Abstract

The authors report a case of a 58-year-old man with coronary artery disease and left ventricular aneurysm following inferior wall infarction, who was implanted with a single chamber cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death. The patient presented with complaints including multiple ICD shocks due to recurrent ventricular tachycardia (VT) resistant to the implemented treatment, decreased quality of life and high level of anxiety associated with multiple hospitalizations. Pharmacological treatment was unsuccessful and led to drug-induced bradycardia. Due to developed pacemaker syndrome the patient underwent ICD upgrade to a dual-chamber device followed by radiofrequency ablation. Despite a number of interventions, VT did not completely disappear. A slight decrease in the number of ICD shocks was observed. After adjustment of the pacing lower rate up to 75 bpm, ventricular arrhythmias were reduced and eventually retreated. In the six months follow-up period no VT was recorded. The authors discuss the current recommendations for VT treatment with the indications for re-ablation or aneurysmectomy. JRCD 2016; 3 (1): 20–23

Authors and Affiliations

Piotr Liszniański

Keywords

Related Articles

Partial anomalous pulmonary venous connection (RCD code: II-3C.0)

A 48-year-old woman was admitted to our institution with a year’s history of uncharacteristic chest pain episodes and decrease in exercise tolerance. A CT lung scan performed nine months earlier revealed an anomalous vei...

Arrhythmias in adult patients after total correction of tetralogy of Fallot (RCD code: V-2B.0)

Improvement of the long‑term survival of patients with Tetralogy of Fallot has been observed in the last few years. Among the late complication arrhythmias are detected most frequently. The aim of this study was to estim...

Right ventricular free wall motion abnormalities as a simple method of assessment in patients with pulmonary hypertension (RCD code: II‐1A.O)

Background: Pulmonary hypertension (PH) is a cardiovascular pathology leading to right-sided heart failure. A qualitative assessment of right ventricular (RV) function in echocardiography provides valuable information on...

Facilitating recognition and grouping the expertise in the main fields of rare cardiovascular diseases

Dear Friends and Colleagues, Dear Readers,We are pleased to deliver at your hands the second issue of your quarterly Journal of Rare Cardiovascular Diseases. The feedback we have received, after launching the Journal in...

Download PDF file
  • EP ID EP244136
  • DOI 10.20418/jrcd.vol3no1.261
  • Views 89
  • Downloads 0

How To Cite

Piotr Liszniański (2016). Patient with multiple ICD interventions (RCD code: V‑2A.O). Journal of Rare Cardiovascular Diseases, 3(1), 20-23. https://europub.co.uk./articles/-A-244136