14 New MEDICAL GADGETS
Journal Title: Indian journal of applied basic medical sciences - Year 2015, Vol 17, Issue 25
Abstract
The Coupler device is implanted into the upper thigh where it is used to create a connection, a sort of fistula, between the iliac artery and iliac vein, allowing some blood to flow between the two. The cath lab procedure takes about forty minutes to complete and doesn’t require sedation, a bit of local anesthetic being sufficient. Once implanted, the device helps reduce peripheral vascular resistance and lead to overall lowering of blood pressure. In the study of 83 patients, there was a reduction of 26·9 mm Hg in hypertension in those receiving the Coupler, while the control group only had a 3·7 mm Hg reduction. Interestingly, the device was shown to benefit even those that tried out renal denervation previously with little luck.
Authors and Affiliations
Janardan Bhatt
24 A STUDY OF COMPARISON BETWEEN SILK LIGATION AND BIPOLAR CAUTERY IN TONSILLECTOMY
Background: Tonsillectomy is one of the most commonly performed surgical procedure. Different techniques and instruments have been used for removal of tonsils along with haemostasis but none of them were found satisfacto...
(11) COMPARISON OF REGIONAL WITH GENERAL ANESTHESIA TECHNIQUES FOR NON CARDIAC SURGEY IN PATIENT WITH ISCHEMIC HEART DISEA
As incidence of ischemic heart disease (IHD) has increased dramatically nowadays, we are finding at least one or two patients of IHD daily in operating lists of our hospital. It is a life style disease and also found in...
3 EFFECT OF ELECTROMAGNETIC FIELDS EMITTED BY CELLULAR PHONE BASE STATION ON HUMAN HEALTH
Background: In today’s world Globalization is the new mantra. It is very difficult not to have technology. But with technology, come certain hazards. The only way to beat these is again, better technology. Electromagneti...
INTEGRATED MEDICAL EDUCATION “CLINICAL /BED SIDE TEACHING CANNOT BE DISINTEGRATED “Dr Janardan Bhatt
The author feels the model very practical to begin to develop an integrated curriculum. But because of its complexity , there is a great problem of acceptance and conceptualization of integrated medical education curric...
10 COMPARATIVE EVALUATION OF EFFICACY OF EMLA CREAM AND A PLACEBO (MOISTURIZING CREAM) IN PRODUCING DERMAL ANALGESIA FOR VENOUS CANNULATION.
BACKGROUND: Venous cannulation is the most commonly performed invasive procedure in hospital patients. It is painful and associated with a high incidence of vasovagal reactions and haemodynamic stress response in patien...