750kv Transmission Line parameter and line Efficiency calculation and the performance of High Voltage alternating current Transmission system using MATLAB program

Abstract

This paper presents the electrical system for 750kv transmission line and also that have been built throughout the world to operate above 700kv.This paper is provides information of system planning, design and programming of the transmission line. In this paper discussed by the over head high voltage 3-phase transmission line problem. The problem is that: 750kv transmission line, it distance 500km, and it handling capacitive load is 2000MW calculate and discussed . These papers also consider that important that the design and operation of transmission line parameter and efficiency determination. The Line losses and the efficiency of transmission are depends on line parameter. These values are greatly influenced by the line constant R, L and C of transmission line. For instant of voltage drop in the line depend upon the above value of line parameter. The system performance is tested under steady-state condition. The line parameters and performance have been calculated by using several MATLAB functions, With MATLAB programs of transmission line analyzes the behavior and parameter of transmission line under the shunt compensation condition to a long transmission line and performance sending end and receiving end. The results after simulation help in designing of extra high voltage long transmission line model. This paper also show that two condition of transmission line: with and without shunt compensation. The intent of this paper is to provide information power handling capacity per circuit, number of circuits sag, average height, L, C, line parameter ABCD, receiving end current, sending end voltage, current, and power, line losses, and line efficiency.

Authors and Affiliations

Alka Szeerin Mansoori , Mrs. Ranjana Nigam Singh

Keywords

Related Articles

Model for Intrusion Detection System with Data Mining 

Today internet has become very popular medium to communicate between users publicly, due to this, lots of intruder has spread across the internet that perform malicious activity and attack to destroy useful informa...

Hybrid Movement Control Algorithm For Restoring Connectivity In WSAN 

Maintaining inter-actor connectivity is very important in WSAN. Failure of one or multiple actors may partition the inter-actor network and obstruct the network operation. This paper presents a combination of two...

Modulation of Generalized Canonical CS-Transform  

In this paper the generalized canonical CS- transform it is extended to the distribution of compact support by using kernel method. The analyticity and modulation theorems are proved for this transform. Also...

An Overview of Partial Shuffle for Database Access Pattern Protection Using Reverse Encryption Algorithm

Encryption of database is an important topic for research, as secure and efficient encryption algorithms are needed that provide the ability to query over encrypted database and allow optimized encryption and decryption...

Download PDF file
  • EP ID EP93544
  • DOI -
  • Views 147
  • Downloads 0

How To Cite

Alka Szeerin Mansoori, Mrs. Ranjana Nigam Singh (2013). 750kv Transmission Line parameter and line Efficiency calculation and the performance of High Voltage alternating current Transmission system using MATLAB program. International Journal of Advanced Research in Computer Engineering & Technology(IJARCET), 2(5), 1743-1748. https://europub.co.uk./articles/-A-93544