A Comparative SEM Evaluation of Cleaning Efficacy of Endo Finisher, Self Adjusting File and Conventional Irrigation Regimen in Simulated Internal Resorptive Defects: An in vitro Study

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 1

Abstract

Introduction: Difficulties associated with the comprehensive cleaning and disinfection of the canals with Internal Resorptive Defects (IRD) still remains a challenge. Hence, it is essential to improvise the existing or develop new root canal cleaning techniques. Aim: To comparatively assess the cleaning efficacy of XP Endo finisher (XP), Self-Adjusting File (SAF) and Conventional Syringe Needle Irrigation (CSNI) from mechanically unreachable region like Internal Root Resorption (IRR) in the middle third of relatively straight root canals. Materials and Methods: The root canals of 30 freshly extracted single rooted human maxillary anterior teeth were prepared using Nickel (Ni) Titanium (Ti) rotary files up till apical size 40. The prepared teeth were longitudinally split into two halves and internal resorptive defects were simulated in each half at uniform level by a demineralisation protocol with nitric acid and Sodium Hypochlorite (NaOCl) solutions in a sequential manner. Thereafter, the prepared specimen halves were reattached and randomly allocated to three equally sized groups (n=10) according to the technique to be used for smear layer/debris removal as follows: Group 1-CSNI, Group 2-SAF, Group 3-XP Endo finisher. The finally prepared specimens were again detached and evaluated for cleaning efficacy using Scanning Electron Microscope (SEM). One-way ANOVA test for means of the group and Post–Hoc Tukey’s test for interrelationship between groups were used for statistical analysis. Results: The mean scores of SAF and XP Endo Finisher group depicted comparatively cleaner canal surfaces and did not differ statistically (p>0.001). However, both the groups showed statistically significant difference with CSNI group (p<0.001). Conclusion: Maximum cleaning efficacy was obtained with SAF and EF followed by CSNI. In the cases of IRD the debris from resorptive defects may be adequately cleaned by both SAF and XP.

Authors and Affiliations

Krupa Rajesh Desai, Naveen Chhabra, Hitesh Gyanani, Satish Gangaramani, Kritika Gupta

Keywords

Related Articles

Is Position Induced Movement Reeducation Helpful on Early Functional Recovery in Acute Adhesive Capsulitis? A Randomised Controlled Trial

ABSTRACT Introduction: Adhesive Capsulitis (AC) is a common musculoskeletal disorder of shoulder caused by inflammation and adhesion formation in the capsule and periarticular structures. The increased nociception from t...

A Comparative study of the Dynamic Hip Screw, the Cemented Bipolar Hemiarthroplasty and the Proximal Femoral Nail for the Treatment of Unstable Intertrochanteric Fractures

Introduction: Fractures of the Intertrochanteric (IT) region are some of the most common fractures encountered by an orthopedic surgeon in his lifetime. With increase in life expectancy, the incidence of these fractures...

Profile and Causes of Low Vision and Blindness in Children from Two Schools for the Blind in Tamil Nadu, Southern India

ABSTRACT Introduction: World Health Organisation’s (WHO) “Vision 2020” right to sight programme gives high priority towards control of ChildHood Blindness (CHB). Blind school screening provides data on the causes of CHB...

Characterisation of Breast Cancer Lesions using Image Processing Based Technique

ABSTRACT Introduction: Characterisation of mammographs deliberates as influential approaches in cataloguing of breast tissues and tumour. In breast, unravelling of nearby tissues in the mammographs is one of the tough pr...

Role of Hypomagnesaemia in Acute Kidney Injury

ABSTRACT Introduction: Acute Kidney Injury (AKI) is a common problem with various causes and consequences like electrolyte disturbances in the form of hypocalcaemia, hypokalemia, hyperkalemia depending on the phase. Seru...

Download PDF file
  • EP ID EP532273
  • DOI 10.7860/JCDR/2018/31275.11122
  • Views 85
  • Downloads 0

How To Cite

Krupa Rajesh Desai, Naveen Chhabra, Hitesh Gyanani, Satish Gangaramani, Kritika Gupta (2018). A Comparative SEM Evaluation of Cleaning Efficacy of Endo Finisher, Self Adjusting File and Conventional Irrigation Regimen in Simulated Internal Resorptive Defects: An in vitro Study. Journal of Clinical and Diagnostic Research, 12(1), 22-26. https://europub.co.uk./articles/-A-532273