A COMPARATIVE STUDY BETWEEN INTRAOPERATIVE CLINICAL AND POSTOPERATIVE RADIOLOGICAL MEASUREMENT OF DISTANCE BETWEEN TIP OF GREATER TROCHANTER TO CENTER OF FEMORAL HEAD IN OPERATED CASES OF HIP HEMIARTHROPLASTY
Journal Title: Journal of Evolution of Medical and Dental Sciences - Year 2018, Vol 7, Issue 52
Abstract
BACKGROUND Hip joint is a polyaxial ball and socket joint. At different stages of gait cycle, joint reaction forces at the hip joint depend on abductor leaver arm which is function of neck length (Offset), neck shaft angle and body weight. During Arthroplasty operation of hip, femoral offset measurement and its restoration to anatomical limit is important. In our study, we have measured the femoral neck length, between two fixed bony points, from the tip of greater trochanter (GT) to the center of the femoral head peroperatively and again post-operatively, from the true size x-ray of the replaced femoral head. We compared this measurement with the postoperative x-ray of normal side hip, to compare, how far normal offset is achieved after operating with various prosthesis (fixed bipolar prosthesis and modular prosthesis) available in the Indian scenario. MATERIALS AND METHODS This is a prospective, comparative study on presentation at in-patient department (IPD). Total 53 patient (22 male and 31 female) above 60 years of age, admitted at our institution ‘Ramakrishna Mission Seva Prathistan (VIMS)’ in the year 2015-16, with intracapsular fracture neck femur of either right or left side were studied. Per-operative measurement was taken during hemiarthroplasty operation using fixed bipolar prosthesis or modular prosthesis (cemented/un-cemented) available in the Indian market. Post-operative measurement taken in the true size x-ray of two fixed points on the operated and normal side. Limb length was measured clinically. The values obtained were compared to establish how far the normal anatomical offset is achieved after hemiarthroplasty operation by using prosthesis manufactured by different companies in India. RESULTS Intraoperative measurement of distance between tip of GT and center of femoral head corresponded with the measurement taken from tip of GT to the prosthetic femoral head. This signifies that we have successfully corrected the offset with available prosthesis with correct surgical technique. There is no significant difference in the postoperative true size x-ray of distance between tip of GT to the center of prosthetic femoral head and the tip of GT with center of femoral head of normal side. CONCLUSION Our study results shows that by opting correct surgical technique and appropriate neck resection, currently available prosthesis (FBP & MBP) in our country can achieve desired neck offset length in comparison to the normal hip and had no significant limb length discrepancy.
Authors and Affiliations
Hiranmoy Deb, Sunny Kumar Mallick
ANTI-CONVULSANT ACTIVITY OF GANAXOLONE ALONE AND IN COMPARISON WITH STANDARD ANTI-EPILEPTIC DRUGS IN RODENT MODELS
[b]BACKGROUND[/b]: Presently, treatment of epilepsy with standard anti-epileptic drugs is associated with a number of shortcomings inviting us to study newer agents that would overcome th...
MAGNETIC RESONANCE IMAGING EVALUATION OF LIGAMENTOUS TEARS OF THE KNEE JOINT AND ASSOCIATION OF MENISCAL TEARS WITH ANTERIOR CRUCIATE LIGAMENT TEARS
Anterior cruciate ligament tears are most commonly sustained sports injury, often occurring in association with meniscal tears and trauma to other ligamentous structures around the knee. Magnetic resonance imagin...
PAROTID DUCT CYST- OUR EXPERIENCE (IN A RURAL MEDICAL COLLEGE)
BACKGROUND Parotid duct sialocele is a rare entity. Patients presented with mostly painless, cystic swelling over the cheek encroaching to the parotid region. Diagnosis was done by FNAC and MR sialogram which revealed th...
MEASUREMENT OF ENDOTRACHEAL TUBE CUFF PRESSURE USING A CONVENTIONAL METHOD IN ELECTIVE SURGERIES
BACKGROUND Endotracheal intubation is the key to airway management in general anaesthesia. It is essential to maintain an optimum endotracheal tube cuff pressure in order to achieve optimum seal, thereby preventing the d...
A COMPARATIVE STUDY OF POST OPERATIVE ASTIGMATISM IN SUPERIOR VERSUS TEMPORAL APPROACH OF MANUAL SMALL INCISION CATARACT SURGERY
[b]BACKGROUND: [/b]Manual small incision cataract surgery is a simple and less expensive technique of cataract surgery but gives visual result almost equivalent to Phacoemulsification. PURPOSE: To compare surgery in...