A Comparison of Iterative Reconstruction and Prone Imaging in Reducing the Inferior Wall Attenuation in Tc-99m Sestamibi Myocardial Perfusion SPECT
Journal Title: Molecular Imaging and Radionuclide Therapy - Year 2017, Vol 26, Issue 3
Abstract
Objective: Prone positioning, iterative reconstruction (IR-OSEM) and electrocardiography (ECG) gating have been demonstrated to improve the specificity of myocardial perfusion SPECT (MPS) in the diagnosis of coronary artery disease. Methods: The gated supine and prone MPS images of 45 patients were reconstructed with both IR-OSEM [supine (SIR) and prone (PIR)] FBPs [supine (SFBP), prone (PFBP)] for comparison. Perfusion, wall motion (WM) and wall thickening were also interpreted semi-quantitatively. Two groups were generated as those with normal or abnormal findings. Segmental myocardial tracer uptake values were noted from four of the reconstructed images from 17 segment model of bullseye. Results: The difference between mean values and the standard deviations of the % tracer uptakes of inferior wall segments were statistically significant in all images. The normalcy rates were highest in PIR images, followed by PFBP and SIR images. The number of patients with any perfusion abnormality were 42, 12, 32, and 6, in SFBP, PFBP, SIR and PIR images, respectively. The six patients with perfusion abnormality in PIR images were re-evaluated with rest images and were diagnosed with a fixed perfusion defect. There was positive correlation between WM and either PFBP or PIR images. Sixteen patients’ WM were evaluated as abnormal while only 6 patients’ perfusions were abnormal in PIR. Conclusion: Prone imaging in addition to a supine perfusion SPECT improves imaging quality of the inferior wall, especially when reconstructed with iterative methods. If prone imaging can not be performed, ECG-gating can also be used as a beneficial method. Keywords: Myocardial perfusion SPECT, attenuation correction, prone positioning, iterative reconstruction
Authors and Affiliations
Duygu Kuşlu, Emel Öztürk
False-positive I-131 Uptakes at Pulmonary Wedge-resection Site and Soft Tissue Lateral to the Femoral Heads in a Patient with Papillary Thyroid Carcinoma
A hyper-metabolic pulmonary nodule was detected on 18F-FDG PET/CT in a 65-year-old woman who had been followed up for 12 years without any complaints following treatment for papillary thyroid cancer (PTC). Wedge resectio...
Thyroid Incidentalomas on 18F-FDG PET/CT: Clinical Significance and Controversies
Objective: The purpose of the current study is to examine the incidence and clinical significance of unexpected focal uptake of 18F-fluorodeoxyglucose (18F-FDG) on positron emission tomography/computed tomography (PET/CT...
Cyclosporine and Vancomycin + Amikacin Induced Hot Kidney Appearance in a Young Adult and a Pediatric Patient
The appearance of a hot kidney on bone scintigraphy is rare and can be seen due to various factors. In our clinic, we observed hot kidney appearance in two patients to whom technetium-99m methylene diphosphonate (Tc-99m...
Incidental Tc-99m Methylene Diphosphonate Uptake in an Active Thyroid Nodule
Tc-99m-methylene diphosphonate (MDP) whole body scintigraphy is the method of choice for detection of metastatic bone diseases. It is primarily used to help diagnose various bone-related conditions such as primary or met...
Diagnostic Value of Bone SPECT/CT in Patients with Suspected Osteomyelitis
Objectives: The aim of our retrospective study was to evaluate the contribution of single photon emission computed tomography/computed tomography (SPECT/CT) to three phase bone scintigraphy/SPECT for the assessment of os...