A DC Circuit Breaker Condition Evaluation Model Based on Health Indexes

Journal Title: Urban Mass Transit - Year 2024, Vol 27, Issue 3

Abstract

[Objective] DC circuit breaker is a key equipment in metro traction power supply system. To improve the reliability of the traction and power supply system through reasonable maintenance strategy, it is necessary to evaluate the health condition of DC circuit breaker accurately. [Method] Health indexes are used to characterize the overall health condition of the equipment and establish a comprehensive evaluation model of the equipment health condition. On the basis that the changes of the equipment characteristic parameters reflect the equipment health condition, evaluation indexes are reasonably selected and a multi-index evaluation system of equipment operating condition is established. With the method of hierarchy and entropy weight, the calculation method of the weight of each sub-index is improved, making the equipment health condition evaluation model more reasonable. The equipment health index is calculated based on the evaluation model, and the service life model based on historical health data is established to fit the trend of the equipment health index, evaluate the future health condition and predict the remaining service life. The proposed evaluation model is validated by the actual data of a traction substation. [Result & Conclusion] The example analysis results show that the proposed evaluation model of DC circuit breaker is effective and rational to some extent in that it can scientifically judge and predict the healthy condition and remaining service life of the DC circuit breaker.

Authors and Affiliations

Delong GUO, Hongwei DUAN, Weijia XU, Jie XU, Mingrui ZHANG

Keywords

Related Articles

Evacuation Solution for Fully Automatic Operation System of Urban Rail Transit

Objective In order to ensure that FAO (fully automatic operation system) can effectively guarantee the safe evacuation of passengers in case of emergency and quickly resume operations after evacuation completion, it is p...

Study on Structural Stability of Shield Launching and Crossing Existing Metro Line in Water-rich Sandy Stratum

Objective In geological conditions with water-rich sandy stratum, research on the structural stability of existing metro lines with new metro line shield launching crossing is relatively scarce. It is essential to summar...

Research Focus at Different Stages of Urban Rail Transit Prophase Works in the New Era

[Objective] In the future, China′s urban development will shift from construction-orientation to governance-orientation. As an important part of the Chinese-style modern social governance system, urban planning is an imp...

Analysis of Surrounding Rock Deformation in the Expansion Excavation Construction Process of Metro Interval Tunnel with Connecting Passage into Forming New Station

Objective The Cruise Home Port Station on Chongqing Rail Transit Line 9 is constructed from in-situ expansion of the existing interval tunnel (including a connecting passage). Due to the complex geological conditions, th...

On-line Monitoring and Analysis of Urban Rail Transit Stray Current

Objective To ensure the safe operation of underground gas pipeline network near URT (urban rail transit) and to mitigate the electrochemical corrosion on the gas pipeline network caused by URT stray current, it is necess...

Download PDF file
  • EP ID EP732805
  • DOI 10.16037/j.1007-869x.2024.03.031
  • Views 30
  • Downloads 0

How To Cite

Delong GUO, Hongwei DUAN, Weijia XU, Jie XU, Mingrui ZHANG (2024). A DC Circuit Breaker Condition Evaluation Model Based on Health Indexes. Urban Mass Transit, 27(3), -. https://europub.co.uk./articles/-A-732805