A Dosimetric Study on Indigenously Developed Heterogeneous Thorax Phantom for Radiation Dose Verification in Carcinoma Lung

Journal Title: Indian Journal of Cancer Education and Research - Year 2019, Vol 7, Issue 1

Abstract

Aim: To design and study the physical and radiological properties of Heterogeneous Thorax Phantom (HTP).Materials and Methods: The Computed Tomography (CT) images of thorax were imported on treatment planning system and analyzed for measuring the density of chest wall tissue, lung and soft tissue behind the lung. The mean and standard deviation of these different densities were noted and analyzed. A HTP with similar density distribution was made using slabs of SP34 and pinewood. A plan was made on actual patient’s CT scan and on HTP by putting 6 MV photon beam of 10x10 cm2 field size and source to surface distance of 100 cms perpendicular to the chest wall using anisotropic analytical algorithm with grid size 0.25 cm. Depths for isodose were measured in both the mediums. The CT scan of HTP was taken at three different interface regions. The doses were planned and measured at these three interface regions using ionization chamber. Measured and planned doses were compared and analyzed. Results: The mean density of the chest wall, lung and soft tissue were found to be 0.94, 0.28 and 0.98 gm/cc respectively on patient’s CT scan, while 0.99, 0.27 and 0.99 gm/cc respectively in HTP. Variation in planned dose and measured dose on HTP at 6 cm, 10 cm and 18 cm depths were found to be 0.47%, 0.81% and 2.4%. Conclusion: Phantom mimicking thorax site along with advanced third generation Monte Carlo based algorithms which are based on biological dose calculation should be used for more accurate dose calculation.

Authors and Affiliations

Virendra Bhandari

Keywords

Related Articles

Can Accurate Pre Operative Assessment of Axillary Lymph Node in Breast Cancer Avoid Axillary Dissection?

Background: The Axillary Lymph node status is of paramount importance in staging, treatment planning, prognosis and survival in Breast Cancer. Hence appropriate investigating criteria for AXLN assessment, which is easy,...

Prospective Analysis of Dosimetric Parameters and Toxicity Outcomes in Cervical Cancer Patients undergoing Concurrent Chemoradiation with Bonemarrow Sparing IMRT Using Spect Correlation

Aim: Study was to evaluate feasibility and benefits of Bone Marrow Sparing IMRT over Standard IMRT. Materials and Methods: Cervical cancer patients undergoing Concurrent Chemo Radiation and brachytherapy and evaluated...

Sebaceous Gland Carcinoma of Upper Eyelid with Parotid Metastasis: A Case Report

Sebaceous gland carcinoma is a rare malignancy which usually arises from periocular region. It accounts of 1–5.5% eyelid malignancies and represents third most common eyelid malignancy. It mostly occurs in elderly women...

Clinical Profile and Outcomes of Acute Myeloid Leukemia: An Institutional Experience from South India

Background: Acute myeloid leukemia is a heterogenous clonal disorder of hematopoietic progenitor cells with different molecular genetic abnormalities, clinical characteristics and variable outcomes with currently availab...

A Clinical Study of Free Flap Reconstruction in Cancer of Oral Cavity

Background: Microvascular free flap surgery for reconstruction of head and neck region in surgical ablation of cancer cases has gained tremendous advancement and interest of oncology and plastic surgeons in recent few y...

Download PDF file
  • EP ID EP633917
  • DOI 10.21088/ijcer.2321.9815.7119.2
  • Views 85
  • Downloads 0

How To Cite

Virendra Bhandari (2019). A Dosimetric Study on Indigenously Developed Heterogeneous Thorax Phantom for Radiation Dose Verification in Carcinoma Lung. Indian Journal of Cancer Education and Research, 7(1), 13-18. https://europub.co.uk./articles/-A-633917