A METHOD FOR DETERMINING LOCATION OF VOLTAGE FLUCTUATIONS SOURCE IN ELECTRIC GRID

Abstract

Purpose. The purpose of work is development of a method of definition of the location of a source of fluctuations of voltage. Methodology. The reasons of emergence of fluctuations of voltage at an arrangement of a source both in power lines, and in the consumer's networks, are connected with changes of consumption and active and reactive capacities. As criterion for definition of the location of a source of fluctuations of voltage we choose change of size of the active power received by reception substation on equivalent communication with system. The source of fluctuations of voltage is external for the consumer if emergence of fluctuations of voltage leads to the coordinated changes of tension and consumed in the area of active power that corresponds to a condition of the positive regulating effect of active loading on voltage (1). The source of fluctuations of voltage is internal for the consumer if emergence of fluctuations of voltage leads to counter changes of tension and consumed in the area of active power that resembles a condition of the negative regulating effect of active loading on voltage superficially (6). Results. The method of definition of the location of a source of fluctuations of voltage in an electric network which, works by the principle of an assessment of correlation of change of power and tension in a power supply network is developed. The method allows to consider shift between extrema of curves of change of voltage of U(t) and power of Pload(t). Originality. The method of definition of an arrangement of a source of fluctuations of voltage is developed. Practical value. The answer to this question where the source of fluctuations of voltage (in the territory of the consumer is located or in an external network) confirmed with the determined calculation, can form a basis of the expert opinion for the solution of legal disputes at an assessment of the damages caused by poor quality of electric energy.

Authors and Affiliations

G. A. Senderovich, A. V. Diachenko

Keywords

Related Articles

LOW VOLTAGE NETWORKS INSULATION MONITORING WITH TWO AND THREE VOLTMETER READOUTS METHODS

Purpose. In the paper there are described methods of two and three voltmeter readouts for insulation resistance periodic measurement in live DC and AC/DC IT networks. A new measuring method for AC/DC networks is proposed...

CLASS STRUCTURE OF ELECTROMECHANICAL ENERGY CONVERTER MODELS WITH UML-DIAGRAMS APPLICATION

Theoretical results are presented, mathematical model formation by means of inheritance from a generalized class template is shown for a general electromechanical energy converter.

PLANT «YUZHCABLE WORKS»: MILESTONES OF THE ROAD (75TH ANNIVERSARY OF THE PLANT «YUZHCABLE WORKS»)

With the history of the creation and development of the Plant «Yuzhcable works», the formation of the national cable industry is connected. The enterprise is the flagship of the industry. Its production potential and the...

A DETERMINATION OF THE FLUX DENSITY IN CORE OF DISTRIBUTION TRANSFORMERS, WHAT BUILT WITH THE COMMON USING OF GRAIN AND NON GRAIN ORIENTED MAGNETIC STEELS

Purpose. The development of calculation method to determinate the flux densities in different parts of the magnetic cores of distribution transformers, what built from different types magnetic steel (mixed core). Methodo...

AUTOMATED FORMATION OF CALCULATION MODELS OF TURBOGENERATORS FOR SOFTWARE ENVIRONMENT FEMM

Attention is paid to the popular FEMM (Finite Element Method Magnetics) program which is effective in the numerical calculations of the magnetic fields of electrical machines. The main problem of its using - high costs i...

Download PDF file
  • EP ID EP297978
  • DOI 10.20998/2074-272X.2016.3.09
  • Views 102
  • Downloads 0

How To Cite

G. A. Senderovich, A. V. Diachenko (2016). A METHOD FOR DETERMINING LOCATION OF VOLTAGE FLUCTUATIONS SOURCE IN ELECTRIC GRID. Електротехніка і Електромеханіка, 0(3), 58-61. https://europub.co.uk./articles/-A-297978