A Mitigation Technique for Inrush Currents in Load Transformers for the Series Voltage Sag Compensator

Abstract

In many countries, high-tech manufacturers concentrate in industry parks. Survey results suggest that 92% of interruption at industrial facilities is voltage sag related. An inrush mitigation technique is proposed and implemented in a synchronous reference frame sag compensator controller. The voltage sag compensator consists of a three phase voltage source inverter and a coupling transformer for serial connection. It is the most cost effective solution against voltage sags. When voltage sag happen, the transformers, which are often installed in front of critical loads for electrical isolation, are exposed to the disfigured voltages and a DC offset will occur in its flux linkage. When the compensator restores the load voltage, the flux linkage will be driven to the level of magnetic saturation and severe inrush current occurs. The compensator is likely to be interrupted because of its own over current protection. This paper proposes an inrush current mitigation technique together with a state-feedback controller for the Voltage sag compensator.

Authors and Affiliations

B. Hari Prasad| Department of Electrical & Electronics Engineering, Annamacharya Institute of Technology& science, India, P. Harsha Vardhan Reddy| Department of Electrical & Electronics Engineering, Annamacharya Institute of Technology& science, India, Dr. M. Padma Lalitha *| Department of Electrical & Electronics Engineering, Annamacharya Institute of Technology& science, India

Keywords

Related Articles

Vulnerability Analysis of Multiple Critical Fault Outages and Adaptive Under Voltage Load Shedding Scenarios in Marmara Region Electrical Power Grid

The utilization of electrical power system has been rising frequently from past to now and there is a need of dependable electrical transmission and distribution networks so as to ensure continuous and balanced energy. B...

A Fuzzy Logic Controller with Tuning Output Scaling Factor for Induction Motor Control Taking Core Loss into Account

This paper presents a design of a fuzzy logic controller (FLC) with tuning output scaling factor for speed control of indirect field oriented induction motor (IM) taking core loss into account. The variation of output sc...

Classification of Leaf Type Using Artificial Neural Networks

A number of shape features for automatic plant recognition based on digital image processing have been proposed by Pauwels et al. in 2009. Then Silva et al in 2014 have presented database comprises 40 diļ¬€erent plant spec...

Application of global thresholding in bread porosity evaluation

The white bread is one of most popular food in Bulgaria. Its quality is defined by standards and control is also standardized. The white bread has four groups of quality parameters - organoleptic, physicochemical, chemic...

Structure-Texture Decomposition of RGB-D Images

In this paper, we study the problem of separating texture from structure in RGB-D images. Our structure preserving image smoothing operator is based on the region covariance smoothing (RCS) method in [16] that we present...

Download PDF file
  • EP ID EP750
  • DOI -
  • Views 610
  • Downloads 44

How To Cite

B. Hari Prasad, P. Harsha Vardhan Reddy, Dr. M. Padma Lalitha * (2014). A Mitigation Technique for Inrush Currents in Load Transformers for the Series Voltage Sag Compensator. International Journal of Intelligent Systems and Applications in Engineering, 2(2), 16-21. https://europub.co.uk./articles/-A-750