A NEW TRANSDUCER OF DOUBLE PROCESSING FOR CAPACITIVE TOMOGRAPHY

Journal Title: Metrology and Measurement Systems - Year 2007, Vol 14, Issue 2

Abstract

The paper presents a new solution of a system for the measurement of small capacities, applied in capacitive tomography. Some known versions of transducers have been discussed. Next, the author has presented his own solution, using a transducer of double processing. In the first step, capacity is changed into frequency, and next the frequency is changed into voltage. The change of capacity to frequency provides introduction of the measuring capacity into the resonant system of a generator. Small capacity changes in the capacitive tomograph influence the changes of the frequency generated by the generator. The proposed solution provides a far better stability of the measurement results related to typical solutions applied in capacitive tomography. The paper presents results of the tests performed for some systems and the obtained results were compared.

Authors and Affiliations

MARIUSZ RZĄSA

Keywords

Related Articles

CONDUCTANCE QUANTIZATION IN FERROMAGNETIC CO NANOWIRES

Room temperature electronic transport properties of ferromagnetic quantum wires have not been yet fully understood, and the role of electronic structure of magnetic atoms in the conductance quantization is still under di...

µ-SCALE CMM: A PROPOSED DIAGNOSTIC TOOL BASED ON EVOLVED DEVIATIONS IN GEOMETRICAL MEASUREMENTS

 µ-scale measurements of dimensional and geometrical features of components require an advanced precise and accurate device such as the CMM machine. Evolved changes in the dimensional and geometrical measurements as refe...

TWO-PARAMETER MEASUREMENTS AND SIGNAL CONDITIONING IN DOUBLE-CURRENT SUPPLY FOUR-TERMINAL RESISTANCE CIRCUITS

A new type of the four-terminal (4T) bridge circuit unconventionally supplied by current sources connected in parallel to opposite arms, named double current bridge (2J) is presented. It has two different outputs from bo...

THE POROACCESSIBILITY PARAMETERS FOR THREE-DIMENSIONAL CHARACTERIZATION OF ORTHOPAEDIC IMPLANTS POROUS COATINGS<br />

The ability of formation of the proper bone-porous implant fixation depends, among others, on the structural-osteoinductive properties of the porous coating covering the orthopaedic implant surface. These properties, des...

AUTOMATIC EXECUTION OF INSPECTION PLANS WITH THE I++ DME INTERFACE FOR INDUSTRIAL COORDINATE MEASUREMENTS

Due to the fast advancement of manufacturing technologies for micro- and nanostructured components and the increasing need for sophisticated inspection methods the paper discusses the prerequisites for automatic executio...

Download PDF file
  • EP ID EP139375
  • DOI -
  • Views 47
  • Downloads 0

How To Cite

MARIUSZ RZĄSA (2007). A NEW TRANSDUCER OF DOUBLE PROCESSING FOR CAPACITIVE TOMOGRAPHY. Metrology and Measurement Systems, 14(2), 291-307. https://europub.co.uk./articles/-A-139375