A novel and inexpensive ballistic gel phantom for ultrasound training

Journal Title: World Journal of Emergency Medicine - Year 2015, Vol 6, Issue 3

Abstract

BACKGROUND: Ultrasonography use is increasing in emergency departments, and ultrasound education is now recommended in resident training. Ultrasound phantoms are used in many institutions for training purposes. The purpose of this study is to describe an inexpensive and simple method to create ultrasound-imaging models for the purpose of education and practice using clear ballistic gel. METHODS: Clear ballistic gel is used to simulate tissue for firing practice and other military evaluations. RESULTS: The transparent and durable ultrasound phantom we produced was clear and contained four vessel lumens. The images obtained using the phantom were of high quality and compared well to normal sonographic anatomy. CONCLUSIONS: The clear ballistic brand gel is unique because it is inexpensive, does not dry out, does not decay, is odorless, and is reusable. The ultrasound images obtained using the phantom are realistic and useful for ultrasound education.

Authors and Affiliations

Keywords

Related Articles

Do medical students studying in the United Kingdom have an adequate factual knowledge of basic life support?

BACKGROUND: Healthcare professionals have a duty to maintain basic life support (BLS) skills. This study aims to evaluate medical students' factual knowledge of BLS and the training they receive. METHODS: A cross-section...

Perforin gene mutations in 77 Chinese patients with lymphomas

BACKGROUND: Perforin gene (PRF1) mutations have been reported in patients with lymphoma, but the prevalence and characteristics of PRF1 mutation have not been identified in Chinese patients with lymphoma. METHODS: Sevent...

Ultrasound curriculum taught by first-year medical students: A four-year experience in Tanzania

BACKGROUND: Diagnostic imaging is an integral aspect of care that is often insufficient, if not altogether absent, in rural and remote regions of low to middle income countries (LMICs) such as Tanzania. The introduction...

Emergency department use among patients from residential aged care facilities under a Hospital in the Nursing Home scheme in public hospitals in Queensland Australia

BACKGROUND: Hospital emergency department (ED) use by patients from residential aged care facilities (RACFs) is not always appropriate, and this calls for interventions to avoid some unnecessary uses. This study aims to...

Empyema and mediastinal abscess in pyriform sinus fistula: A case report

Though notorious for its tendency to induce recurrent neck abscess, pyriform sinus fistula is of importance despite its rarity. It usually presents diagnostic and therapeutic challenges. Because of post-infectious fibros...

Download PDF file
  • EP ID EP470210
  • DOI -
  • Views 55
  • Downloads 0

How To Cite

(2015). A novel and inexpensive ballistic gel phantom for ultrasound training. World Journal of Emergency Medicine, 6(3), 225-228. https://europub.co.uk./articles/-A-470210