A phantom-based study for assessing the error and uncertainty of a neuronavigation system
Journal Title: TecnoLógicas - Year 2017, Vol 20, Issue 38
Abstract
This document describes a calibration protocol with the intention to introduce a guide to standardize the metrological vocabulary among manufacturers of image-guided surgery systems. Two stages were developed to measure the errors and estimate the uncertainty of a neuronavigator in different situations, on the first one it was determined a mechanical error on a virtual model of an acrylic phantom, on the second it was determined a coordinate error on the computerized axial tomography scan of the same phantom. Ten standard coordinates of the phantom were compared with the coordinates generated by the NeuroCPS. After measurement model was established, there were identified the sources of uncertainty and the data was processed according the guide to the expression of uncertainty in measurement.
Authors and Affiliations
Natalia Izquierdo-Cifuentes, Genaro Daza-Santacoloma, Walter Serna-Serna
Mathematical model of photovoltaic systems for distributed maximum power point tracking
This paper presents a model of photovoltaic generation systems oriented to evaluate the performance of distributed maximum power point tracking algorithms. The model considers the series connection of n module-converter...
Technical-economic feasibility analysis of micro grids integrating fuel cells in non-interconnected zones in Colombia
The sustainable power solutions provided tonon-interconnected zonesshould bebased on the renewable energy resources available in each area. Thispresents a challenge for the techno-economic feasibility of alternativ...
Effect of the concentration of magnetite on the structure, electrical and magnetic properties of a polyester resin-based composite
This study reports the effect of the concentration of magnetite powders (Fe3O4) on the electrical and magnetic properties of a resin-based composite of thermoset polyester. The samples were prepare...
Evaluation of FeCl3 and PAC for the potabilization of water with high content of color and low turbidity
The water source for supply from moorland is characterized by its high color and low turbidity, which represents an inconvenience to be considered in most water treatment plants. Internationally, studies have been carrie...
Analysis of the efficiency of a virtualoptical multiplexing method, by using theta modulation
We present an efficient virtual-optical multiplexing method for compressing information contained in gray level images. The efficiency is measured using three parameters: quality factors of...