A Prospective controlled comparative study of haemodynamic responses, intubating conditions to laryngoscopy and tracheal intubation by using Macintosh vs. Mc Coy blade laryngoscope

Journal Title: MRIMS Journal of Health Sciences - Year 2018, Vol 6, Issue 1

Abstract

Abstract: Background: The invention of McCoy blade in the early 1990s is a modification of the Macintosh blade with a hinged tip. The McCoy blade reduces the amount of force applied during laryngoscopy and endotracheal intubation, thus the increased reflex haemodynamic changes in response to tracheal intubation becomes less significant. Objective: To determine the advantages of McCoy blade laryngoscope in obtunding the pressor response, better glottic visualization and ease of intubation during laryngoscopy and endotracheal intubation as compared to Macintosh blade laryngoscope. Methods: The present study was done on 60 adult patients of ASA I and II, between the age group of 20 to 50 years. We observed the haemodynamic changes, glottic view and ease of intubation by using either Macintosh or McCoy blade laryngoscope during general anesthesia at laryngoscopy and endotracheal intubation. The changes in HR, SBP, DBP, and MAP were recorded before induction, at laryngoscopy and intubation and at 1 min, 3 min and 5 min after tracheal intubation. Glottic view obtained on laryngoscope was compared as per Cormack and Lehene grading. Tracheal intubation grading was also compared between the groups. Complications during the procedure like arrhythmias, injury, and bleeding were noted. Results: In our study, a significant haemodynamic changes were observed in both the groups following laryngoscopy and endotracheal intubation. The rise in HR, SBP, DBP and MAP were more significant with Macintosh blade laryngoscope, where as better visualization of the glottis, ease of intubation and less haemodynamic changes were noted with McCoy blade laryngoscope. Conclusion: McCoy blade laryngoscope produces significantly less marked haemodynamic changes, better glottic view and ease of intubation as compared to Macintosh blade laryngoscope during laryngoscopy and tracheal intubation. Key words: Macintosh blade, McCoy blade, endotracheal intubation, Haemodynamic response, glottic view

Authors and Affiliations

Sarada Devi V, Lakshmi Narasimham M, Manjula VR, Saroj P, Surender P

Keywords

Related Articles

Posner Schlossman Syndrome - A Case Report

A 23 year old female patient presented to Ophthalmology OPD with complaints of left sided headache since one month, it was sudden in onset and was associated with redness, watering, photophobia and blurring of vision. T...

Left Ventricular Pseudo aneurysm: A case report

Rupture of the free wall of the left ventricle (LV) is a catastrophic complication occurring in 4% of patients after myocardial infarction (MI) and in 23% of those who die of MI. It is caused by myocardial rupture contai...

A Study of Depression and Metabolic Syndrome (Mets) In Patients of Type 2 Diabetes Mellitus (T2DM) At Rural Tertiary Care Hospital

Abstract: Background: Co-morbid depression may occur among diabetic patients, and may be associated with poor outcomes. However, despite large diabetic population, literature of depression in T2DM from India is scare. O...

Prevalence of ABO & Rh blood groups in patients visiting Malla Reddy Health City, Suraram, Hyderabad

Background: Blood groups of different people have different antigenic and immune properties, so that, antibodies in the plasma of one blood react with antigens on the surface of the red cells of another blood type. If pr...

Social Customs among mothers during pregnancy in Karimnagar district, Telangana

Background: Customs in a community will play a key role while providing health services. Misunderstandings about these customs result in poor services. Objectives: 1) to know the various social customs practiced by moth...

Download PDF file
  • EP ID EP474714
  • DOI -
  • Views 115
  • Downloads 0

How To Cite

Sarada Devi V, Lakshmi Narasimham M, Manjula VR, Saroj P, Surender P (2018). A Prospective controlled comparative study of haemodynamic responses, intubating conditions to laryngoscopy and tracheal intubation by using Macintosh vs. Mc Coy blade laryngoscope. MRIMS Journal of Health Sciences, 6(1), 1-5. https://europub.co.uk./articles/-A-474714