Abstract

Aim To study the effects of exposure to electromagnetic radiations from cell phone on HumansMaterials and Methods A prospective crosssectional study was conducted in a secluded room of the Central Laboratory of the Medical College where use of electronic devises is prohibited The study was conducted on 25 healthy male subjects and 25 health female subjects in the age range of 1825 years of age In post night fasting state the study subjects were isolated in the secluded room for 3 hours to prevent any exposure to electromagnetic radiations Blood sample is collected and divided into two aliquots one is control sample not exposed and test sample exposed to EMR with strength of 0471 WKg for 30 minutes from a distance of 5cm The samples were evaluated for blood cell count blood indices and blood sugar levels Nerve conduction study was done on median nerve prior to and after exposure to EMR for 5 minutesResults Significant increase was observed in Mean Corpuscular Volume MCV p 0012 and Neutrophil count p 0026 in test sample compared to control sample Significant decrease was observed in Mean Corpuscular Haemoglobin Concentration MCHC p 0049 and blood sugar levels pNerve conduction study on median nerve has shown significant increase in conduction velocity p 0014Conclusion The study has shown that even a limited exposure to EMR in recommended strengths can cause significant changes in haematological parameters and conduction velocity of nerve Keywords Haematological Electro magnetic radiations Nerve conduction study

Authors and Affiliations

Mohd Rasheeduddin Imran, Shweta K, Aryan Singh, Mohd Abrar Hassan

Keywords

Related Articles

Morphometric considerations of articular surfaces of calcaneum, occurrence of enthesophytes and evolutionary significance of cuboidal facet

Introduction: Pattern of talar articular facets on the superior aspect of calcaneum significantly influence in causation of subtalar arthritis. Enthesophytes from calcaneum is a major cause of heel pain. Evolutionary mod...

Visual evoked potential changes in pre-diabetics, type 2 diabetics and normal subjects

Introduction Diabetes mellitus type 2 is the most common metabolic disorder and diabetic retinopathy is the leading cause of blindness Persistent hyperglycemia leads to damage of microvasculature supplying the retina and...

Correlation of Hemoglobin concentration with Body Mass Index among medical students

Introduction: Obesity and anemia are considered as the double burden of malnutrition. Significant changes in life style, stressful working conditions, consumption of quick preserved foods, snacks and soft drinks of low n...

LVMI: A detrimental paradigm shift of left ventricular geometry and function in accidently detected hypertensives

Introduction Left ventricular hypertrophy LVH is an important predictor of mortality and morbidity in hypertension leading to hypertensive heart disease HHD Left ventricular mass LVM therefore chiefly determines the geom...

An anatomical study on types of calcaneal facets on talus and co relation between squatting facets and angles of neck

Introduction Talus is a short compact bone with muscular attachments Its head and body are oriented in specific manner Thus it is subjected to modifications due to change of direction of forces by adapting different post...

Download PDF file
  • EP ID EP476117
  • DOI 10.18231/2394-2126.2018.0092
  • Views 87
  • Downloads 0

How To Cite

Mohd Rasheeduddin Imran, Shweta K, Aryan Singh, Mohd Abrar Hassan (2018). A study on haematological and physiological effects of electromagnetic radiation from global system of communication. Indian Journal of Clinical Anatomy and Physiology, 5(3), 397-401. https://europub.co.uk./articles/-A-476117