Aassessment of the reliability of measurements madę with PEL38 podometric platform
Journal Title: Fizjoterapia Polska - Year 2009, Vol 9, Issue 2
Abstract
Background. Advances in measurement techniques have enabled the development of computer-assisted podometric platforms that measure sub-pedal pressure distribution. The PEL 38 is an example ofsuch a platform that offers sufficient measurement accuracy and is easy and reliable to use. The aim of the study was to assess the reliability and repeatability of measurements madę with the PEL 38 platform. Materiał and methods. The study group comprised 30 subjects (16 F, 14 M) aged 20 years of whom nonę was a Professional athlete and nonę suffered from any diseases of musculoskeletal system. A PEL 38 platform with TWINN 99 software was used to measure the length (cm) and width (cm) ofboth feet, sole areas (sq. cm), subpedal pressures (N/sq. cm) and centres of pressure from centres ofsupport (cm). The results were subjected to standard statistical analysis and statistical significance ofthe differences between repeated individual measurements and between corresponding measurements madę by two independent examiners was determined with Cronbach's Alpha test. The same test was also used to assess the reliability of the measurements. Results. Cronbach's Alpha test of variance homogeneity which was used to estimate differences between measurements obtained with the PEL 38 platform by two independent examiners, indicated no significant differences, which proves the concordance and, consequently comparability of the results. Conclusions. The analysis of measurements madę with the PEL 38 platform confirmed their reliability and comparability, which renders the method fit for use both for diagnostic purposes and in screening and research studies.
Authors and Affiliations
Piotr Bartkowiak, Joanna Boch-Kmieciak, Paweł Szulc, Jacek Lewandowski
Computer-Based Medical Decision Support Systems - history, development, comparison of systems in selected European countries and the United States
The world is facing many challenges connected with the need to increase health care effectiveness globally. One of the reasons behind the need to improve and optimise healthcare systems is change in the population age st...
Magnetic Fields Physiotherapeutic Effectiveness Coefficient After Dental Implant Implantation
The purpose of this study was to estimate the most efficient effect of steady and variable field magnetic stimulation and magnetic stimulation with LED light therapy in case of sensation of pains after the dental implant...
Balance Versus Postural Stability and Its Disorders in Patients after Ischemic Stroke – Theoretical Study
The aim of this study is to explain the differences between balance and postural stability, and the changes which occur in these traits in patients after stroke. Human being has the natural ability to stand on two feet a...
Przykłady ćwiczeń funkcjonalnych zalecanych w profilaktyce zaburzeń posturalnych w płaszczyźnie strzałkowej u dzieci w wieku przedszkolnym i wczesnoszkolnym. Praca nad nawykami
Niedoskonałość postawy obserwowana u dzieci wieku przedszkolnym i wczesnoszkolnym jest stanem fizjologicznym i wynika z braku umiejętności stabilizacji odcinka lędźwiowego oraz sąsiednich segmentów ciała, a także z niedo...
Aspects of spontaneous activity in afferent nerve fibres
In some situations, nerve cells display peculiar behaviour, referred to as spontaneous activity. It consists in generating spontaneous action potentials, which are not directly triggered by an external factor. They are m...