Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran
Journal Title: Journal of Biomedical Physics and Engineering - Year 2011, Vol 1, Issue 1
Abstract
Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, it is one of the most important tools in order to achieve or demonstrate the level of radiation protection. Methods: Yazd province has only one private nuclear medicine (NM) center. In this center, two NM technologists exposed to radioactive patients during radiopharmacuticals preparation were monitored. NM technologists have to be close to the patient during radiopharmaceutical injection and patient positioning on the gamma camera table. An electronic personal dosimeter DKG-21 Ecotest made in Ukraine which records the ambient dose equivalent rate and equivalent dose was used to monitor the radiation exposure to the technologists and to record the accumulation dose in mSv throughout a working day. This study was accomplished between the time period of January to June 2011. The dosimeter is designed to measure individual equivalent dose Hp(10). The dose range of gamma radiation was 0.01 mSv to 1 Sv and the energy range 0.05 to 6 MeV which was suitable for NM procedures. The planar and tomography NM images were performed by the 2 technologists in the morning and afternoon shifts. Results: The average monthly occupational dose of each technologist was approximately 0.6 mSv. Their annual doses were 6.6 and 8.8 mSv, respectively. They were lower than the maximum permissible dose of 20 mSv/y. Total number of NM procedures performed in this NM center during June 2010 to June 2011 was 3265. Conclusion: The use of APD for monitoring the NM technologists is a useful tool to check compliance with regulatory dose limits and radiation protection principals.
Authors and Affiliations
F. Bouzarjomehri, V. Tsapaki
Can Evolutionary-based Brain Map Be Used as a Complementary Diagnostic Tool with fMRI, CT and PET for Schizophrenic Patients?
Objective: In this research, a new approach termed “evolutionary-based brain map” is presented as a diagnostic tool to classify schizophrenic and control subjects by distinguishing their electroencephalogram (EEG) featur...
Optimization of Brain Tumor MR Image Classification Accuracy Using Optimal Threshold, PCA and Training ANFIS with Different Repetitions
Background: One of the leading causes of death is brain tumors. Accurate tumor classification leads to appropriate decision making and providing the most efficient treatment to the patients. This study aims to optimize b...
Detection and Characterization of Human Teeth Caries Using 2D Correlation Raman Spectroscopy
Background: Carious lesions are formed by a complex process of chemical interaction between dental enamel and its environment. They can cause cavities and pain, and are expensive to fix. It is hard to characterize in viv...
Electromagnetic Fields of Mobile Phone Jammer Exposure on Blood Factors in Rats
Background: The increasing demand for using mobile phones has led to increasing mobile phone jammers as well. On the other hand, reports show that exposure to electromagnetic field causes an increase in the incidence of...
Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI
Background: Dynamic contrast enhanced magnetic resonance imaging (DCEMRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prost...