Alternative Mathematical Form for Determining the Effectiveness of High-LET Radiations at Lower Doses Region

Journal Title: International Journal of Radiology and Imaging Technology - Year 2016, Vol 2, Issue 1

Abstract

The Effectiveness of lower doses of high-LET radiations is not accurately determined by using energy-based physical parameters such as absorbed dose and radio-sensitivity parameters. Therefore, an attempt has been carried out in this research to propose alternative parameter that capable to quantify the effectiveness of these high LET radiations at lower doses regions. The linear energy transfer and mean free path for linear primary ionization are employed as distinct parameters to achieve this objective. A new mathematical form of the effectiveness of high-LET radiations at lower doses region has been formulated. Based on this parameter, the optimized effectiveness of high-LET radiations occurs while the energy of higher LET particles is deposited at spacing of 2 nm for linear primary ionizations.

Authors and Affiliations

Keywords

Related Articles

Comparison of Arterial Spin Labeling and Dynamic Susceptibility Contrast-Enhanced MR Perfusion in Differentiating Tumor Recurrence from Treatment-Related Changes

Introduction: MR dynamic susceptibility contrast-enhanced perfusion (DSC) has demonstrated utility in the evaluation of follow-up malignant CNS neoplasms. Preliminary studies suggest Arterial Spin Labeling (ASL) perfusio...

Inferior Mesenteric Arteriovenous Malformation Presenting as Ischemic Colitis After an Acute Episode of Campylobacter Jejuni Colitis

An arteriovenous malformation (AVM) of the inferior mesenteric artery is a rare entity that could be associated with ischemia. We present the case of a 54-year-old male with ischemic colitis after an acute episode of Cam...

A Retrospective Comparison of Pre-Operative Computed Tomographic Angiography (CTA) Performed at 100 versus 120 kVp Tube Energies and Surgical Findings at Laparoscopic Donor Nephrectomy

Introduction:A retrospective review of patients who underwent preoperative Computed Tomographic Angiography (CTA) prior to living laparoscopic renal donation was performed. Image quality and accuracy were compared at 120...

Does Improved Technology in SPECT Myocardial Perfusion Imaging Reduce Downstream Costs? An Observational Study

Background: Advances in myocardial perfusion imaging (MPI), including CT attenuation correction (CTAC) and advanced image reconstruction algorithms, result in improved image quality, thus reducing equivocal or false posi...

On Long Term Effects of Low Power Laser Therapy on Bone Repair: A Demonstrative Study by Synchrotron Radiation-based Phase-Contrast Microtomography

Laser effects on fracture healing are still controversial and require further quantitative 3D measures of newly formed bone microstructural parameters. We performed a demonstrative investigation, by synchrotron radiation...

Download PDF file
  • EP ID EP352466
  • DOI 10.23937/2572-3235.1510009
  • Views 139
  • Downloads 0

How To Cite

(2016). Alternative Mathematical Form for Determining the Effectiveness of High-LET Radiations at Lower Doses Region. International Journal of Radiology and Imaging Technology, 2(1), 1-4. https://europub.co.uk./articles/-A-352466