Aluminium glazed partitions with timber insulation inserts – fire resistance tests results depending on the type of used wood

Abstract

This paper discusses the main problems related to the fire resistance of aluminium glazed partitions with timber insulation inserts, including the tests methodology and way of classification of this type of elements. Moreover, the paper presents the comparison of fire resistance test results of glazed partition with timber insulation inserts test specimens, depending on the type of wood used as an insulation insert. Keywords:

Authors and Affiliations

BARTŁOMIEJ SĘDŁAK, DANIEL IZYDORCZYK, PAWEŁ SULIK

Keywords

Related Articles

Lowering of formaldehyde emission from wood based panels by modification of polycondensation adhesives with natural fillers, additives and activators

Lowering of formaldehyde emission from wood based panels by modification of polycondensation adhesives with natural fillers, additives and activators. Modification of polycondensation resins were directed to urea-formald...

Computertomograph und Bandsägen steigern Ausbeute in großen Sägewerken

Computertomograph und Bandsägen steigern Ausbeute in großen Sägewerken. In dem Referat wurde das erste Deutsche Sägewerk mit Computertomograph-Scanner und Bandsägen beschrieben. Es ist ein Sägewerk zum Einschnitt von Ele...

The Influence of Traditional Wood Finishing Substances on Surface Roughness

The Influence of Traditional Wood Finishing Substances on Surface Roughness. The purpose of the project was to assess the traditional substances used for finishing wooden parquets and their influence on surface roughness...

Timber-concrete composite floor under fire conditions – comparative analysis

Timber-concrete composite floor under fire conditions – comparative analysis.This article presents the results of a calculative analysis of a defined timber-concrete composite floor designed at ULS and SLS states conditi...

Design and execution risks of safety of the structure made from glued laminated timber

In this paper safety risks of an existing structure made from glued laminated timber were presented. The hazard of safety comes from an inappropriate design and a structural approach as well as from the changes in design...

Download PDF file
  • EP ID EP362303
  • DOI -
  • Views 64
  • Downloads 0

How To Cite

BARTŁOMIEJ SĘDŁAK, DANIEL IZYDORCZYK, PAWEŁ SULIK (2016). Aluminium glazed partitions with timber insulation inserts – fire resistance tests results depending on the type of used wood. Annals of WULS, Forestry and Wood Technology; Zeszyty naukowe SGGW, 96(1), 102-106. https://europub.co.uk./articles/-A-362303