An Advanced Current Controller Implemented with ANN Technique for Three Phase Shunt Active Power Filter

Abstract

This paper proposes an advanced control strategy to enhance performance of shunt active power filter (APF). The proposed control scheme requires only two current sensors at the supply side and does not need a harmonic detector. In order to make the supply currents sinusoidal, an effective harmonic compensation method is developed with the ANN technique. The absence of the harmonic detector not only simplifies the control scheme but also significantly improves the accuracy of the APF, since the control performance is no longer affected by the performance of the harmonic process. Furthermore tracking, the total cost to implement the proposed APF becomes lower, owing to the minimized current sensors and the use of a four-switch threephase inverter.

Authors and Affiliations

A. Sundararao, CH. Sujatha

Keywords

Related Articles

Synthesis for a Face Video of Target Subject

synthesizing a face video of a target subject that nothing but the mimicry of the expressions of a source subject in the input video is facial expression retargeting in video. Facial expression retargeting has applicati...

Facial Expression Recognition: A Study

Facial Expressions are the outcome of the moments done through face muscles with respect in the changes on face. These expressions may represent the person’s internal emotional stage as well as thought in a body languag...

Implementation of The K-Means Clustering Algorithm to Analyze the User Interest by Analyzing the University Web Log Servers

Web Usage mining is considered as one of the very important category of the web data mining, which manages the extraction of useful and interesting data from the web log documents. Web utilization has turned out to be t...

Effects of the Addition of Pistachio Shell Particles on the Properties of Polyurethane Matrix Composite

In this research, a composite material-based polyurethane matrix with natural resources is prepared via the casting method and the effects of the weight fractions (2.5-12.5) wt% of pistachio shell particles on the prope...

A Review: Design of 16 bit Arithmetic and Logical unit using Vivado 14.7 and Implementation on Basys 3 FPGA Board

The paper primarily deals with review for the construction of arithmetic Logic Unit (ALU) using Hardware Description Language (HDL) using Xilinx Vivado 14.7 and implement them on Field Programmable Gate Arrays (FPGAs) t...

Download PDF file
  • EP ID EP19470
  • DOI -
  • Views 283
  • Downloads 4

How To Cite

A. Sundararao, CH. Sujatha (2015). An Advanced Current Controller Implemented with ANN Technique for Three Phase Shunt Active Power Filter. International Journal for Research in Applied Science and Engineering Technology (IJRASET), 3(1), -. https://europub.co.uk./articles/-A-19470