An automated dispensing system for improving medication timing in the emergency department

Journal Title: World Journal of Emergency Medicine - Year 2012, Vol 3, Issue 2

Abstract

BACKGROUND: Numerous medical conditions require timely medication administration in the emergency department (ED). Automated dispensing systems (ADSs) store premixed common doses at the point-of-care to minimize time to administration, but the use of such automation to improved time to medication administration has not been studied. Since vancomycin is a commonly used empiric antimicrobial, we sought to quantify the effect of using an ADS on time to drug delivery in patients presenting to the ED. The study aimed to determine the efficacy of utilizing an ADS to improve time to administration of vancomycin and determine any negative effects on dosing appropriateness. METHODS: The institional review board approved the retrospective quality improvement study took place in a single, urban academic tertiary care ED with an annual census of 80 000. Study subjects were all patients receiving vancomycin for the management of sepsis between March 1 to September 30, 2008 and the same time period in 2009. The primary outcome was the proportion of patients who received vancomycin within one hour of bed placement and the secondary outcome was dosing appropriateness. RESULTS: Sixty-three patients had weight and dosing information available (29 before and 34 after intervention) and were included in the study. Before intervention, no patient received vancomycin in less than 60 minutes, while after intervention 14.7% of the patients received it in less than 60 minutes (difference in proportions 14.7%, 95% CI 0.39%-30.0%, P=0.04). A similar proportion of the patients received correct dosing before and after intervention (44.8% vs. 41.2%, difference in proportions 3.7%, 95% CI -20.0%-26.7%, P=0.770). CONCLUSION: The use of an ADS may improve the timing of medication administration in patients presenting to the ED without affecting dosing appropriateness.

Authors and Affiliations

Keywords

Related Articles

An evaluation of compliance and performance following the introduction of the Inter-Facility Transport Triage Guideline

BACKGROUND: In Hong Kong, the reorganization of healthcare frame work for better utilization of resources has led to an increase in the frequency of inter-facility transport in recent years. An Inter-Facility Transport T...

The use of outcome feedback by emergency medicine physicians: Results of a physician survey

BACKGROUND: Feedback on patient outcomes is invaluable to the practice of emergency medicine but examples of effective forms of feedback have not been well characterized in the literature. We describe one system of emerg...

Prognosis of patients with shock receiving vasopressors

BACKGROUND: Consensus guidelines suggested that both dopamine and norepinephrine may be used, but specific doses are not recommended. The aim of this study is to determine the predictive role of vasopressors in patients...

Computed tomography angiography-negative aortic dissection in a patient using Phencyclidine

Although the average age of diagnosis for aortic dissection is 63,[1] this case demonstrates the need to consider AD in younger patients, particularly in the presence of risk factors or in the absence of another reasonab...

Effect of tumor necrosis factor-α on ventricular arrhythmias in rats with acute myocardial infarction in vivo

BACKGROUND: Acute myocardial infarction (AMI) is an acute cardiovascular emergency. This study was undertaken to assess the effect of tumor necrosis factor-α (TNF-α) on ventricular arrhythmias induced by AMI in rats in v...

Download PDF file
  • EP ID EP472800
  • DOI -
  • Views 66
  • Downloads 0

How To Cite

(2012). An automated dispensing system for improving medication timing in the emergency department. World Journal of Emergency Medicine, 3(2), 102-107. https://europub.co.uk./articles/-A-472800