An Interphase Short Circuit Fault Location Method of 10 kV Distribution Network
Journal Title: 河南科技大学学报(自然科学版) - Year 2019, Vol 40, Issue 5
Abstract
In view of the problem that when there was a branch load before interphase short-circuiting fault point in the distribution network line, the result of impedance legal position had large deviation, a secondary positioning algorithm was put forward to reduce the position error of the phase-phase short circuit faultly.Firstly, the fault types were identified by analyzing the principle of impedance method.Then, the fault point was located by the one-time location algorithm. When there was branch load before the fault point, the fault result was corrected by combining with the line topology. Lastly, the feasibility and accuracy of secondary position algorithm were analyzed by calculation example.The reslts show that when the fault distance is within 20 km, the positioning error of the secondary positioning algorithrn is less than 1 km, and the error rate is less than 10%.The positioning accuracy is high and has good engineering practicability.
Authors and Affiliations
Lei CHEN, Yuedong ZHAN, Qingsheng TIAN, Zenan MA
Research and Application of AC-20 Modified Ratio with Foamed Asphalt Mixture
The AC-20 modified foam asphalt mixture ratio was studied with a highway project.The optimum foaming condition of asphalt was determined by measuring the physical index of asphalt foaming.The gradation design of mineral...
Exact Solutions and Backlund Transform of Five Dispersion Equation
By using the extended Clarkson and Kruskal (CK) method, the five order dispersion equation with variable coefficients was transformed into the five order dispersion equation with constant coefficients, and the equivalent...
Effect of Flight Forbidden Area on Sector Dynamic Capacity
In order to make use of the aerospace resource reasonably and improve the operational efficiency and safety of air traffic, the sector dynamic capacity was studied. The definition of the flight forbidden area ( FFA) was...
Optimal Hour-Ahead Scheduling of Micro-Grid Considering Wind Power Uncertainty
The supply of the micro-grid was the coordination of wind power generator and fuel/gas generator.Because the wind power generation in the next hour cannot be predicted accurately, the uncertainty will largely affect the...
Cloning and Subcellular Localization of ARGONAUTE1 Gene from Populus euphratica
The full length open reading frame (ORF) of homologous of AGO1 (AtAGO1) in Arabidopsis from Populus euphratica was cloned by using reverse transcription-polymerase chain reaction (RT-PCR) method based on Populus genome d...