Analysis of radiation resistance control and evaluation methods in terms of model (Zn-O)-GaP LEDs Introduction and problem statement

Abstract

Introduction and problem statement. Research relevance of most important parameters of LEDs — resistance to ionizing radiation — for their use in civilian hardware, aerospace, nuclear and radioelectronics onboard equipment is shown. Samples and experimental technique. Samples obtaining method for studying of neutron irradiation influence on the LEDs is indicated. The neutron irradiation influence on the basic characteristics (light intensity) given current and voltage is investigated. Experimental results interpretation shows that for this model current radiative component associated with electrons injection in the optically active p-region. Radiative excitons recombination occurs at the (Zn-O)-complexes, the concentration of which is a linear function. An experimental study light intensity dependences of fluens and damage constant finding. Theoretically and experimentally investigated the light intensity dependence of neutron irradiation fluens at given current. The (IV0/IV) dependencies from fluens neutrons with energy >= 0,1 MeV and fixed voltage of 1,65 V is presented. It shown that light intensity reduction while irradiation at the fixed current is much faster than at the fixed voltage. The calculation formula and (IV0/IV) dependence from neutrons fluens for set of 25 LEDs at nominal current 10 mA are received. Conclusions. The neutron irradiation influence with energy above 0,1 and 2,65 MeV on the light intensity red glow (Zn-O)-LEDs is indicated. It shown that damage constant is proportional to the neutrons momentum. The calculated light intensity dependence from fluens at given current is received.

Authors and Affiliations

O. Abdullaiev, I. Ryzhikov, N. Rudenko, Yu. Adamenko

Keywords

Related Articles

Determination of measurement error of spurious signals in power network

Is defined the additional errors to the errors of the measuring device brings the equivalent of a network or adapter (filter) used to measure the spurious high-frequency signals in power network.

Expert estimation methods of radioelectronic tools consumer properties.

The application expedience and stages expert evaluation, the conditions of the expert method use, the composition of the expert commission requirements and the qualification of the expert criterions are considered. The d...

Neural-genetic method for synthesis of antennas and microwave devices

A neural-genetic concept is proposed for synthesis of antennas and microwave devices. A device to be optimized is modeled by artificial neural networks and synthesis is made by genetic algorithm based inversion of the ar...

Adaptive filtration of parameters of the movement UAV according to sensor networks based on measurements of the received signal strength

Introduction. In modern conditions increasingly important begin to play unmanned aerial vehicles (UAVs), which give rise to a new class of threats. This leads to the need to develop security systems that solve tasks of d...

Resonance filtration by two-phase resonators

Introduction. Resonance spectral filtration has an exceptional importance for many applica-tions. Resonators based on reflectors with antiphase reflection coefficients — two-phase res-onators — are proposed. Single-phase...

Download PDF file
  • EP ID EP308963
  • DOI 10.20535/RADAP.2014.56.112-120
  • Views 66
  • Downloads 0

How To Cite

O. Abdullaiev, I. Ryzhikov, N. Rudenko, Yu. Adamenko (2014). Analysis of radiation resistance control and evaluation methods in terms of model (Zn-O)-GaP LEDs Introduction and problem statement. Вісник НТУУ КПІ. Серія Радіотехніка, Радіоапаратобудування, 0(56), 112-120. https://europub.co.uk./articles/-A-308963