ANALYSIS OF STRESS IN STEEL AND CONCRETE IN CFST PUSH-OUT TEST SAMPLES
Journal Title: Civil and Environmental Engineering Reports - Year 2017, Vol 3, Issue 26
Abstract
The paper presents the analysis of stress in steel and concrete in CFST composite elements subjected to push-out tests. Two analytical models of stress distribution are presented. The bond at the interface between steel and concrete in the initial phase of the push-out test is provided by the adhesion. Until the force reach a certain value, the slip between both materials does not occur or it is negligibly small, what ensures full composite action of the specimen. In the first analytical model the full bond between both materials was assumed. This model allows to estimate value of the force for which the local loss of adhesion in given cross section begins. In the second model it was assumed that the bond stress distribution is constant along the shear transfer length of the specimen. Based on that the formulas for triangle distribution of stress in steel and concrete for the maximum push-out force were derived and compared with the experimental results. Both models can be used to better understand the mechanisms of interaction between steel and concrete in composite steel-concrete columns.
Authors and Affiliations
Bartosz GRZESZYKOWSKI, Magdalena SZADKOWSKA, Elżbieta SZMIGIERA
ASPECTS OF FOREST MANAGEMENT IN THE MAINTAINING OF FOREST ENVIRONMENT
Forest management is a scientific discipline designed to develop methods of maintaining forest areas and to ensure the sustainable development of forest resources in terms and conditions of multifunctional forestry. This...
THE PROBLEMS OF EASTERN ORTHODOX CHURCH BUILDINGS OF HISTORICAL VALUE – CHANGING USES OVER THE YEARS
There are many Eastern Orthodox church buildings throughout the Lublin Province. Over the years, these architectural objects have undergone multiple transformations, both in terms of changing religious denominations and...
BIODETERIORATION DUE TO IMPROPER EXPLOITATION OF EXTERNAL FACADES
Unaesthetic stains and deposits often form on external facades (especially those facing the north) in places where barriers were installed on them. Such places include, for example: fragments of facades in which external...
A SIMPLIFIED MODEL FOR AN N-LAYER ELASTIC FOUNDATION
The paper presents a model for an elastic foundation consisting of a finite number of homogeneous and isotropic layers. The simplified continuous elastic media with internal constraints introduced by R Switka [1] has bee...
PROPERTIES OF THE ORGANIC FRACTION DIRECTED TO BIOSTABILIZATION IN MBT INSTALLATIONS DURING THE HEATING SEASON
In the professional literature, there is no information about the sieve and morphological composition OFMSW (<80 mm) subjected to biological processing in MBT installations during the heating season. Knowledge about the...