Analysis of the Effect of Phantom CT Scan Diameter Variations on Radiation Dose with IndoseCT

Abstract

The dose received by a patient who performs a CT scan is influenced by several factors, namely slice thickness, pitch, position and size of the patient, range of scanning and type of scanning. The amount of radiation dose received from the scan also depends on phantom geometry, form and material. The method of calculating a patient's dose on a CT scan is known as the Computed Tomography Dose Index (CTDI). According to research that has already been carried out, it is explained that CTDI represents only the surface dose of the body. SSDE is then used to calculate the central dose of phantom and phantom edge. The purpose of this study was to determine the dosage size for variations in phantom diameter and SSDE values with the IndoseCT program for variations in phantom diameter. The measurement method in this study was carried out using a piranha detector and IndoseCT software. The results of the study found that there were differences in the values of CTDIc, CTDIw, and CTDIvol, each having a range of 0.93% to 147.96%, 26.65% to 62.48%, 11.51% to 41.46%. SSDE values for phantom size 8 cm, 16 cm, 24 cm, 32 cm and 40 cm respectively are as follows: 29 mGy, 23.09 mGy, 16.86 mGy, 12.35 mGy, 9.27 mGy. The conclusion of this study is that the greater the effective diameter of phantom the smaller the SSDE.

Authors and Affiliations

ntan Andriani

Keywords

Related Articles

Isaacs syndrome : A rare clinical entity

Neuromyotonia is a rare syndrome of continuous motor unit activity of peripheral nerve origin that manifests as various combinations of muscle stiffness, cramps, twitching and weakness. Isaacs syndrome is a form of acqui...

A study to evaluate the effectiveness of foot massage therapy to reduce pain among rheumatoid arthritis patients in selected hospital at Bangalore

The aim of the study was to evaluate the effectiveness of foot massage therapy to reduce pain among rheumatoid arthritis patients; the research approach adopted for this study was an evaluative approach. Pre –experimenta...

Anxiety and depression levels in obese college going students

This study was carried out to find out anxiety and depression level in obese college going students. This study was conducted on 70 subjects .The DASS Questionnaire was given to all the subjects. This questionnaire conta...

To study the awareness about the pharmacovigilance in the postgraduate residents at a tertiary care hospital- a kap study

Background Pharmacovigilance is the science related to detection, evaluation and prevention of Adverse drug reactions (ADRs). Safety of patients and safe use of medicines are high requisition that has emerged practice of...

Perceptions and experiences of physicians regarding integration of clinical pharmacists in health practices: A survey of hospitals of Karachi, Pakistan

Introduction Drug-related problems are frequent and may result in reduced quality of life, and even morbidity and mortality. Studies have shown that clinical pharmacists can identify and prevent drug-related problems. A...

Download PDF file
  • EP ID EP535823
  • DOI -
  • Views 58
  • Downloads 0

How To Cite

ntan Andriani (2019). Analysis of the Effect of Phantom CT Scan Diameter Variations on Radiation Dose with IndoseCT. International Journal of Allied Medical Sciences and Clinical Research, 7(1), 21-27. https://europub.co.uk./articles/-A-535823