Analytical investigation of magnetic field effects on Proton lateral deflection and penetrating depth in the water phantom: A relativistic approach

Journal Title: Electronic Physician - Year 2017, Vol 9, Issue 12

Abstract

BACKGROUND: Integrated proton therapy - MRI systems are capable of delivering high doses to the target tissues near sensitive organs and achieve better therapeutic results; however, the applied magnetic field for imaging, influences the protons path, changes the penetration depth and deflects the particles, laterally, leading to dose distribution variations. OBJECTIVE: To determine the effects of a magnetic field on the range and the lateral deflection of protons, analytically. METHODS: An analytical survey based on protons energy and range power law relation, without using small angle assumption was done. The penetration depth and lateral deflection of protons with therapeutic energy ranges 60-250 MeV in the presence of uniform magnetic fields of 0-10T intensities, were calculated analytically. Calculations were done for relativistic conditions with Mathematica software version 7.0, and MATLAB 7.0 was applied to plot curves and curve fittings. RESULTS: In the presence of a magnetic field, the depth of Bragg peak was decreased and it was shifted laterally. A second order polynomial model with power equation for its coefficients and a power model with quadratic polynomial coefficients predicted the maximum lateral deflection (ymax) and maximum penetration depth (zmax) variations with energy and magnetic field intensity, respectively. CONCLUSION: The applied correction for deflection angle will give more reliable results in initial energy of 250 MeV and 3T magnetic field intensity. For lower energies and magnetic field intensities the differences are negligible, clinically

Authors and Affiliations

Mohammad Javad Tahmasebi Birgani, Nahid Chegeni, Mansour Zabihzadeh, Marziyeh Tahmasbi

Keywords

Related Articles

The comparison of Neoprene palumbo and Genu direxa stable orthosis effects on pain and activity of daily living in patients with patellofemoral syndrome: a randomized blinded clinical trial.

Patellofemoral pain syndrome (PFPS) is one of the most common disorders of the knee. Conservative approaches, as well as surgery, can decrease pain and the syndrome's progress effectively.

Step Test: a method for evaluating maximum oxygen consumption to determine the ability kind of work among students of medical emergencies

INTRODUCTION: Maximum oxygen consumption shows the maximum oxygen rate of muscle oxygenation that is acceptable in many cases, to measure the fitness between person and the desired job. Given that medical emergencies are...

Brain Natriuretic Peptide in Liver Cirrhosis and Fatty Liver: Correlation with Cardiac Performance.

The aims of the present study were to assess the serum BNP level in patients with post hepatitis C liver cirrhosis and patients with fatty liver and to determine the correlation between BNP and the severity of liver dise...

Comparison of Central Corneal Thickness Measurements by Pentacam and Ultrasound Pachymetry in Normal Myopic Patients

INTRODUCTION: Precise measurement of corneal thickness is of crucial importance in corneal refractive procedures. The aim of this work is to compare the central corneal thickness measurements using Scheimpflug imaging (P...

Nutrichemistry, a means of preventing and healing chronic diseases

The burden of chronic diseases, such as cancer, diabetes, heart disease, and hypertension is so heavy that health care systems' provisions are hampered in many countries. The high incidence of chronic diseases might be m...

Download PDF file
  • EP ID EP333330
  • DOI 10.19082/5932
  • Views 106
  • Downloads 0

How To Cite

Mohammad Javad Tahmasebi Birgani, Nahid Chegeni, Mansour Zabihzadeh, Marziyeh Tahmasbi (2017). Analytical investigation of magnetic field effects on Proton lateral deflection and penetrating depth in the water phantom: A relativistic approach. Electronic Physician, 9(12), 5932-5939. https://europub.co.uk./articles/-A-333330