Aplikasi Filter Pasif pada Beban Inverter Tiga Fase Berbeban

Abstract

Harmonic is one of sinusoidal components, one wave period from which having multiple frequency of its fundamental frequency one, leading to electrical power quality problems. Harmonic distortion in term of voltage and current ones, generally is due to non linier impedance. Inverter is one of example of it. The result of the tests were showed that voltage harmonic distortion at inverter did not exceed the IEEE 519-1992 maximum limitation of 5%. While current harmonic distortion for each phase exceed 102,3%, 89,94% and 72,67%. After using passive filter, the total harmonic distortion (THD) current became 5,458 %, 6,118% and 5,968% for each phase.

Authors and Affiliations

Wahri Sunanda

Keywords

Related Articles

Analisa Kinerja PAPR pada Sistem OWDM Menggunakan Wavelet Packet

In wireless communications, demand to provide high-speed data services with good performance raises new techniques to increase spectrum efficiency and improved signal quality due to frequency selective fading. OFDM is a...

Sistem Informasi Objek Wisata Jelitik Kabupaten Bangka Berbasis Webserver

Bangka has a beautiful tourist destination and attract tourists to visit, especially coastal tourism. One of them is a tourist destination in the village of Jelitik with beautiful and interesting beach tourism potential...

Rancang Bangun Unipolar PWM untuk Pengendalian Rangkaian H-Bridge Menggunakan Operational Amplifier

Unipolar PWM control technique carried out by comparing triangular wave with two control voltages. The resulting pulses are used to control H-Bridge circuit. The technique can be done by using the functions of the operat...

Optimasi Jaringan 4G LTE (Long Term Evolution) pada Kota Balikpapan

Long Term Evolution (LTE) is a fourth generation (4G) technology developed by the 3rd Generation Partnership Project (3GPP). LTE is capable of providing downlink speeds of up to 100 Mbps and 50 Mbps uplink. This research...

Disain Kontroler PI dengan Decoupling pada Sistem Kendali Level Coupled Tank

The problems on the Coupled Tank control level is the existence of disturbance in the flow that supplies tank would make unstability response, so it could happen the cross interaction between input and output. PI control...

Download PDF file
  • EP ID EP549023
  • DOI 10.33019/ecotipe.v1i1.45
  • Views 89
  • Downloads 0

How To Cite

Wahri Sunanda (2014). Aplikasi Filter Pasif pada Beban Inverter Tiga Fase Berbeban. Jurnal Ecotipe (Electronic, Control, Telecommunication, Information, and Power Engineering), 1(1), 42-48. https://europub.co.uk./articles/-A-549023