Are the Tidal Volumes Used in Intensive Care Units Suitable for Lung Protective Ventilation? Can Training Ensure Compatibility?

Journal Title: Turkish Journal of Intensive Care - Year 2020, Vol 18, Issue 3

Abstract

Objective: Low tidal volume (VT) and lung protective ventilation (LPV) are recommended to prevent lung injury associated with invasive mechanical ventilation (IMV). Present study aimed to determine the patients with risk of high VT application, whether VT calculated according ideal body weight (IBW) values are suitable for the recommended (6-8 mL/kg) and whether a questionnaire on the issue contributes to IMV suitable for LPV. Materials and Methods: Present study is conducted as a multicenter point - prevalence study in the intensive care units of three hospitals in Bursa. Non-ARDS patients receiving IMV and patients who were older than 18 years were included in the study. IMV parameters and demographic data of the patients were collected. Then, the physicians responsible of ventilatory management completed a questionnaire about LPV strategies and VT values required according to the IVA were shown. After 24 hours, mechanical ventilation parameters were re-collected. Body mass index (BMI), average tidal volume applied [VTmean = minute volume (MV)/respiratory rate (RR)] and VTmean for IBW (VTmean/IBW) values were calculated. Results: Fifty-six patients were included in the study. There were 33 male patients (58.9%) and the mean age of the patients was 65.43±18.87 years. The mean BMI of the patients was 27.84±7.0. The most commonly used ventilation mode was synchronized intermittent mandatory ventilation (75%). The VTmean was 549.32±151.00 mL (VTmean/IBW =9.31±3.07 mL/kg). According to VTmean/IBW, for the use of large VTs, being female (10.77±2.74 mL/kg) and having BMI ≥30 (10.82±3.80 mL/kg) posed significantly higher risk than being male (8.31±2.91 mL/kg) and having BMI <30 (8.67±2.47 mL/ kg) (p=0.002, p=0.015 respectively). The results showed a significant decrease (p=0.026) in VTmean/IBW (8.81±3.49 mL/kg) values after the physicians completed LPV questionnaire and were shown the VT values (predicted by IBW). Conclusion: VTmean/IBW values were found to be higher than 6-8 mL/kg, the recommended value for LPV. Ventilation with high VT was associated with female gender and having a BMI of ≥30. Completing the LPV questionnaire and seeing the VT values (predicted by IBW) contributed to the number of the patients ventilated with VT values suitable LPV.

Authors and Affiliations

Pınar Küçükdemirci Kaya, Halil Erkan Sayan, Murad Kaya, Nermin Kelebek Girgin

Keywords

Related Articles

The Effect of Endotracheal Tube Cuff Pressure Control on the Development of Microaspiration and Ventilator- Associated Pneumonia: Systematic Review

Objective: To investigate the effect of endotracheal tube cuff pressure control on microaspiration and ventilator-associated pneumonia. Materials and Methods: This study was created by using the Preferred Reporting Item...

A Pregnant Woman with Jaundice in the Intensive Care Unit

Acute fatty liver of pregnancy (AFLP) is a life-threatening disorder characterized by maternal liver failure, and it occurs in the third trimester of pregnancy or postpartum period. The resultant effects include coagulop...

Comparison of the Effects of Standard and Diabetesspecific Dietary Products on Tight Blood Glucose Control in Critically Ill Patients

Objective: Nutritional support is a part of intensive care unit therapy. In our study, we investigated the effects of diabetes-specific enteral formula and standard enteral formula on tight blood glucose control and insu...

Perioperative Management of Bleeding Due to Uterine Atony/Rupture in a Parturient after Vaginal Delivery and Intensive Care Unit Follow-up: Pharmacological, Surgical and Interventional Therapies

We aimed to present perioperative management of bleeding due to uterine atony and/or rupture and postoperative intensive care unit (ICU) follow-up of a parturient after spontaneous vaginal delivery. A 36-year-old parturi...

Download PDF file
  • EP ID EP688774
  • DOI 10.4274/tybd.galenos.2019.43434
  • Views 129
  • Downloads 0

How To Cite

Pınar Küçükdemirci Kaya, Halil Erkan Sayan, Murad Kaya, Nermin Kelebek Girgin (2020). Are the Tidal Volumes Used in Intensive Care Units Suitable for Lung Protective Ventilation? Can Training Ensure Compatibility?. Turkish Journal of Intensive Care, 18(3), -. https://europub.co.uk./articles/-A-688774