Assessment of Effect of the length of Orthodontic Mini-screw Implants on their long-term stability: An Observational Study

Journal Title: Journal of Advanced Medical and Dental Sciences Research - Year 2018, Vol 6, Issue 4

Abstract

Background: Bone anchorage devices can be either osseointegrated or non-osseointegrated depending on their bone-endosseous surface interface and design features. Since their introduction, orthodontic miniscrews have shifted the paradigm of anchorage in orthodontics and tooth movements that were once difficult have become easier. Hence; we planned the present study to assess the effect of the length of orthodontic mini-screw implants on their long-term stability. Materials & methods: The present study included assessment of effect of the length of orthodontic mini-screw implants on their long-term stability. A total of 8 patients were included in the present study. Calculation of optical bone density (OPD) was done in all the cases. Each patient received both the 6- and 8-mm-long Temporary intraoral skeletal anchorage devices (TISAD/TAD), in randomly selected mandibular quadrants (left or right). Loading of the TISAD/TAD was done with forces parallel to the occlusal plane by using NiTi springs. Results: In the patients with 8 mm TISD length, stability was seen in 75 percent of the cases, while failure occurred in 25 percent of the cases. In the patients with 6 mm TISD length, stability was seen in 62.5 percent of the cases, while failure occurred in 37.5 percent of the cases. Conclusion: In comparison to the 6 mm mini-screws, the stability of 8 mm orthodontic mini-screw implants is higher.

Authors and Affiliations

Ritika Singh

Keywords

Related Articles

Tobacco Use Among Young Students and its Influence on Role Models

Background: Smoking is a noteworthy general wellbeing, especially in youthful grown-ups between the ages of 18 and 25. The primary target of this examination is to discover the use of tobacco among Young Students and its...

Variation in Anatomical Position of Lingula in relation to Ramus Osteotomy assessed by Cone Beam Computed Tomography (CBCT): A Systematic Review

Dentofacial deformities can occur in both maxilla and mandible. The available treatment modality for treating such cases is Bilateral Sagittal Split Ramus Osteotomy (BSSO) in case of mandibular deformities. Identificatio...

ADVERTISEMENT

ADVERTISEMENT

Analysis of Deaths due to Snake Bites- A Forensic Study

Background: Human snake encounters with negative results such as animal death, habitat destruction, injuries to people, injuries to wildlife and the like are common. The present study was conducted to assess the cases of...

Comparing the Sealing Ability of Different Intra Orifice Barriers using two Different Sealers

Objectives: The purpose of this study was to compare the sealing ability of Biodentine, Mineral Trioxide Aggregate (MTA) and Glass Ionomer Cement (GIC) when used over gutta-percha as intracanal sealing materials. The stu...

Download PDF file
  • EP ID EP544768
  • DOI -
  • Views 123
  • Downloads 0

How To Cite

Ritika Singh (2018). Assessment of Effect of the length of Orthodontic Mini-screw Implants on their long-term stability: An Observational Study. Journal of Advanced Medical and Dental Sciences Research, 6(4), 142-145. https://europub.co.uk./articles/-A-544768