Assessment of Medical X-Ray Radiographic Screen-Films in Different Spatial Frequencies According To Detective Quantum Efficiency Computation

Journal Title: International Journal of Fundamental Physical Sciences - Year 2012, Vol 2, Issue 1

Abstract

In medical imaging, to make better images there are some measures such as detective quantum efficiency (DQE) and noise equivalent quanta (NEQ) used to evaluate the image quality of each imaging system. Detective quantum efficiency (DQE) is one of the important measures in the assessment of image quality and detector performance. DQE of two types of screen-films namely Lanex Regular/T-Mat G/RA and Lanex Regular/T-Mat L/RA were determined using MTF and NPS data, separately. Moreover, gamma was calculated from characteristic curves for each screen film and photon flounce was estimated using published literature. DQE of the screen-films were computed for three optical densities 0.7, 1.0 and 1.4. The results show Lanex Regular/T-Mat G has better DQE than Lanex Regular/T-Mat L -especially at low frequency with higher contrast for diagnostic radiology purposes.

Authors and Affiliations

Mohammad Khanmirzaei, Wan Muhamad Wan Hassan

Keywords

Related Articles

Inertial Forces and the Laws of Dynamics

The basic concepts and laws of classical dynamics are analyzed from the standpoint of their adequacy to the physical nature of material bodies and to the dynamical processes. What Newton called absolute immovable space i...

On how proton radius shrinkage can be connected with ‎Lorentz factor violation

    Views Several new experimental findings have shown that atomic nuclei cannot have a similar structure of that adopted in the ‎Standard Nuclear Physics (SNP), because there are insurmountable obstacles...

The Photoelectric Effects: Radiation Based With Atomic Model

A Radiation Magnetic Force (Fm-R) frequency controlled formula is derived, signifying the embaddement of magnetic force in Electromagnetic Radiation (EM-R) similar in nature to Radiation Magnetic Energy (EmR ) or Planck’...

A Study on Activity Concentration of Natural Radionuclide of Building Materials in Kochi

The study of natural radiation exposure is of importance because it accounts for the largest contribution to the collective dose for the world population from all sources. Extent of exposure to natural radiation depends...

A geometric representation for visualizing relativistic length and time measurement

The simplest solution of Einstein's field equations is Schwarzschild solution. This solution is not able to describe for any nonspherical shaped objects. Some stars and galaxies are in ellipsoidal. Consequently, the...

Download PDF file
  • EP ID EP599311
  • DOI 10.14331/ijfps.2012.330026
  • Views 120
  • Downloads 0

How To Cite

Mohammad Khanmirzaei, Wan Muhamad Wan Hassan (2012). Assessment of Medical X-Ray Radiographic Screen-Films in Different Spatial Frequencies According To Detective Quantum Efficiency Computation. International Journal of Fundamental Physical Sciences, 2(1), 9-11. https://europub.co.uk./articles/-A-599311