Assessment of Pupil Diameters in Pseudoexfoliation Syndrome under Scotopic, Mesopic, Photopic and Dynamic Conditions Using Infrared Pupillometer (Assessment of Pupil Diameters in Pseudoexfoliation Syndrome)

Journal Title: Journal of Advances in Medicine and Medical Research - Year 2015, Vol 7, Issue 11

Abstract

Aim: Our study aims to assess the mean pupil size under scotopic, mesopic, photopic and dynamic conditions in patients with PXS. Methodology: This study was performed in Ophthalmology Clinic at İstanbul Bakırköy Dr.Sadi Konuk Training and Research Hospital. Fourty-six patients with PXS and 46 age and sex matched controls were included in the prospective study. The subjects were allowed at least 3 minute to adapt to the lighting condition in the room. Pupil diameters were measured with infrared (IR) pupillometer integrated within CSO Sirius Corneal Topographer (Costruzione Strumenti Oftalmici S.r.l,Italy ) by the same examiner. The measurements were taken in scotopic, mesopic, photopic and dynamic conditions. Statistical analyses were evaluated. Results: Mean pupil diameter were significantly lower in the PXS group than control group for all measurements. Scotopic and mesopic pupil size were significantly lower in the PXS group than control group (p=0.0001). Also photopic and dynamic pupil size were significantly lower in the PXS group than control group (p=0.014, p=0.013). Conclusion: The results suggest that pupillary light response in patients with PXS significantly was affected not only in scotopic and mesopic conditions but also in photopic and dynamic conditions.

Authors and Affiliations

Ulviye Yiğit, Ismail Umut Onur, Ali Kutlay Tufan, Mehmet Fatih Aşula

Keywords

Related Articles

Bisphosphonate-associated Atypical Fractures that are not “Atypical Femoral Fractures”

Aims: Responding to the steadily increasing number of unusual subtrochanteric and mid-shaft femoral (ST/FS) fractures in persons treated with the bisphosphonate drugs since the index cases were described in 2003, the Ame...

Tissue Penetration of Bipolar Electrosurgery at Different Power Settings

Introduction: Bipolar electro-surgery is used in all disciplines of surgery to aid in haemostasis. Although common sense dictates tissue penetration will be effected by power settings, no formal evaluation of this effect...

The Performance of the Finnish Diabetes Risk Score (FINDRISC) Questionaire for Screening Individuals with Undiagnosed Type 2 Diabetes and Dysglycaemia in Nigeria

Introduction: The Finnish Diabetes Risk Score (FINDRISC) questionnaire is a non-invasive, cheap, and easy to use screening tool to estimate future risk of diabetes development and detection of asymptomatic type 2 diabete...

Minor Side Effects, Tolerance and Discontinuation of Oral Contraception among Women in Rural Cambodia

Contraceptive prevalence in Cambodia is relatively low, while maternal mortality, newborn mortality, and projected rates of abortion are high. Fears of side effects and health concerns appear to be the leading reasons fo...

Comparison of Shear Bond Strength of Different Orthodontic Metal Bracket-bases Bonded on Enamel Surface – an In vitro Study

Aim: To compare the shear bond strength of different metal bracket bases bonded on enamel surface and further to evaluate the Adhesive Remnant Index score to localize the sites of adhesive fracture. Materials and Methods...

Download PDF file
  • EP ID EP347994
  • DOI 10.9734/BJMMR/2015/16423
  • Views 53
  • Downloads 0

How To Cite

Ulviye Yiğit, Ismail Umut Onur, Ali Kutlay Tufan, Mehmet Fatih Aşula (2015). Assessment of Pupil Diameters in Pseudoexfoliation Syndrome under Scotopic, Mesopic, Photopic and Dynamic Conditions Using Infrared Pupillometer (Assessment of Pupil Diameters in Pseudoexfoliation Syndrome). Journal of Advances in Medicine and Medical Research, 7(11), 877-883. https://europub.co.uk./articles/-A-347994