Abstract
Introduction. The switching-modulation commutator (SMC) in the front part is used in design of the highly-sensitive radiometric systems with modulation type. These devices may restrict a band of the input broadband signals from the object of interest. This leads to a reduction of the sensitivity and accuracy. The purpose is to perform calculations of the optimal parameters of SMC using generalized complex values (GCV). Main body. The transients in the shoulders of SMC under the impact of control signal F0(t), divergence of values of the reflectivity (Г) and transfer coefficient (S) in the different channels, also radio-thermal parasitic noises of the adjacent elements may affect the value of errors that are made by SMC are shown in this article. Estimations of the GCV values dependence are performed under the deviation of the SMC parameters by ±10%. Conclusions. Using SMC in the front part of the radiometric system we can obtain the maximum ratio “signal-noise” that provided by wavelength 1.9 mm, equality of the modules of SMC elements with distinction of its phase values. The modules of the GCV from antennas X1 and X2 are differ in 2.1 times and the phase parts – in 1.3 times. The sensitivity of the GCV is different towards to the deviation (±10%) of the optimal parameters (module and phase parts) of the RF circuits (radiometric devices) and could vary from hundredth of a percent to 90%.
Authors and Affiliations
V. Kutsenko, A. Yanenko, K. Shevchenko
Coupling coefficients of the Spherical dielectric microresonators with whispering gallery modes
The calculation results of the Spherical dielectric microresonators coupling coefficients with whispering gallery modes are presented. Microresonator coupling coefficients as a functions of main parameters is considered....
Peculiarities of lowintensity microwave radiation of materials for physiotherapy
Introduction. The results of low-intensity EMI of natural materials studies used for thermal physiotherapy are reviewed. Research results. In a result of radiometric measurements of weak signals at frequency of 45 GHz a...
Technical approach to optimal utilization of telecommunication system bandwidth
At the present time, the opportuneness of commercial operations requires the convergence of different types of traffic and the ensuring of the necessary quality of services related to the transmission of data, voice and...
The phase noise of low noise transistor microwave oscillators
The phase noise direct measurement feature is analysed.
Concerning to coherency of electromagnetic waves, light in particular (part 2)
Quantum-packet model of light beam was proposed. This model organically reconciles wave-corpuscle properties of light beam and explains nature of it coherency and physics sense of it parameters.