Axial translaminar screw placement using three-dimensional fluoroscopy-based navigation.

Journal Title: Singapore Medical Journal - Year 2011, Vol 52, Issue 1

Abstract

To circumvent the risk to the vertebral artery with C2 pars or pedicle screws, C2 laminar screws were considered as a method for rigid fixation of the axis. Although considered to be a relatively safe method, ventral spinal canal violations have been reported. Three-dimensional (3D) fluoroscopy-based image guidance may enhance the accuracy and safety of the technique. There is only one previous report in the literature on its use in the placement of C2 laminar screws. The purpose of this study was to assess the accuracy of C2 translaminar screws inserted using 3D fluoroscopy-based navigation.

Authors and Affiliations

S Rajasekaran, A Avadhani, A P Shetty

Keywords

Related Articles

Adefovir-induced Stevens-Johnson syndrome and toxic epidermal necrolysis overlap syndrome.

An increasing number of patients with chronic hepatitis B infection are being treated with the newly licensed drug, adefovir. It is an acyclic nucleoside phosphonate that is relatively safe in the dosage generally used f...

Cholestasis and biliary dilatation associated with chronic ketamine abuse: a case series.

Ketamine is a dissociative anaesthetic agent that is still widely used in veterinary and human medicine. It is increasingly being used as a recreational hallucinogenic drug. Chronic ketamine abuse is known to account for...

ECG ST segment elevation in patients with chest pain.

We discussed three cases of ST elevation myocardial infarction with ST elevation in the inferoposterior territory and anterior territory, and more uncommonly, concomitant ST elevations in the anterior and inferior electr...

Rare mechanical complication of myocardial infarction: isolated right ventricle free wall rupture.

Rupture of the left ventricular free wall is a dramatic complication of acute myocardial infarction (MI) and occurs in about ten percent of patients with fatal acute MI. However, there are limited reports about right ven...

Higher-order multiple births in Abakaliki, Southeast Nigeria.

Higher-order multiple births have implications for perinatal and maternal morbidity and mortality. This study aimed to determine the incidence and outcomes of higher-order multiple pregnancies in a rural area in Southeas...

Download PDF file
  • EP ID EP155410
  • DOI -
  • Views 97
  • Downloads 0

How To Cite

S Rajasekaran, A Avadhani, A P Shetty (2011). Axial translaminar screw placement using three-dimensional fluoroscopy-based navigation.. Singapore Medical Journal, 52(1), 15-18. https://europub.co.uk./articles/-A-155410