Behavior of Hollow I-Beams Reactive Powder Concrete with Opening for Pure Torque
Journal Title: International Journal of Civil, Structural, Environmental and Infrastructure Engineering Research and Development (IJCSEIERD) - Year 2017, Vol 7, Issue 5
Abstract
A series of nine, I section reinforced concrete hollow beams, by use of Reactive Powder Concrete (RPC), with square and circular web opening. The geometry and main reinforcement of all specimens are same, and was investigated under the effect of pure torsion. The main parameters taking into account, in present paper are hollow beam size, the location of hollow opening geometry and opening size. The torque caused the first crack, that was recorded and the angle of twist generated from this torque, was calculated for different parameters mentioned above. The results indicated that, the crack torques for a first crack decrease in presence of hollow and opening, and the crack torques decrease when the size of hollow and opening increased.
Authors and Affiliations
Ali Sabah Ahmed Alamli, Sarmad Haitham Abdulameer
Geometry and Leaning of Alhadba Minaret
There is great effort of planning to rebuild the recently destructed Alhadba minaret in Mosul. A major requirement is to study the original shape and materials. During the past years, there was a considerable amount of l...
Experimental Behavior of Clay Masonry Wall with Opening Under Effect of Lateral Forces
This paper presents an experimental test program, on eight clay brick masonry walls, under the effect of lateral forces. The effect of opening, boundary condition and vertical compression forces were assumed as, variable...
Hardened Properties of Polyethylene Terephthalate based Concrete
Disposing of waste plastic materials has always been point of concern. As PET bottles are of nonbiodegradable character, their decomposition is main concern regarding environmental perception. Recycling or reusing is onl...
Quantifying Impact on Water Environment by Using Fuzzy Set Theory
Assessment of the impact of developmental activities on water environment is difficult to measure as numbers of parameters are involved in the overall assessment of water quality. Efforts have been taken to develop Water...
Applying Strain-Sensing Technology for Monitoring and Diagnosing Peel-Based Deterioration of Tiled Exterior Walls
Various levels of deterioration can occur in buildings, because of aging or improper management. In recent years, the deterioration of tiled exterior walls of the buildings in Taiwan has become increasingly severe. This...