بررسي کارايي فرايند الکتروپرسولفات در تخريب غلظتهاي بالاي آنتيبيوتيک سفترياکسون از پسابهاي دارويي
Journal Title: آب و فاضلاب - Year 2016, Vol 27, Issue 4
Abstract
Efficiency of Electro/Persulfate (EPS) Process in Degrading High Concentrations of Ceftriaxone in Pharmaceutical Effluents Abstract Two-valent iron ions can be used to activate persuphate anions. The objective of the present study was to investigate the electrical activation of persuphate anions and to determine the efficiency of electro-persulphate in the removal of ceftriaxone antibiotic from synthetic pharmaceutical effluents. For this purpose, a reactor (with an effective volume of 1 L) equipped with iron electrodes connected to a DC power supply was used and the effects of pH, voltage, persulphate content, and ceftriaxone initial concentration on the efficiency of the process were studied. Moreover, electrode corrosion, synergistic effects of the parameters studied, reaction kinetics, and chemical oxygen demand (COD) removal were studied. Results showed that the variables had a significant effect on process efficiency such that 96% of the ceftriaxone in the effluent was removed under the following optimum conditions: pH: 3, voltage: 10 V, a persulphate concentration of 50 mM/L, a ceftriaxone initial concentration of 0.18 mM/L, and a reaction time of 45 min. However, removal efficiency declined when the above conditions changed. It was also observed that COD removal was 72% in the optimum reaction time. Moreover, the process kintetics was found to be a first-order one. Application of an electrical process to active persulphate anion is assoiated with such advantages as reduced iron consumption and high antibiotic removal efficiency. Based on the results obtained, the proposed method may be recommended as an alternative for treating persistent pollutants to reduce environmental pollution.
Authors and Affiliations
Mohammadreza Samarghandi, Amir Shabanlo, Elham Nazari, Mahboobeh Sadri, Jamal Mehralipour
بررسي الگوي مصرف آب خانگي با رويکرد بخشبندي مصرفکنندگان (مطالعه موردي: مصرفکنندگان آب خانگي شهرستان ايلام)
Investigating the Consumption Pattern of Domestic Water by Segmentation Approach for Water Consumers (Case Study: Domestic Water Consumers in Ilam City) The aim of this study is to identify domestic water consumption am...
تحليل ريسک شبکههاي جمعآوري رواناب شهري با استفاده از تصميمگيري چند معياره مکاني (مطالعه موردي: منطقه 11 تهران) Risk Assessment of the Urban Runoff Collection Networks Using Spatial Multi Criteria Decision-Making (Case Study: District 11 of Tehran)
Abstract Urban runoff management as well as collecting and transferring surface waters are the major concerns for officials and managers in urban affairs. The Multiple components of runoff drainage systems, the close in...
ارزيابي سيستم منابع آب با رويکرد يكپارچه بر اساس چارچوب حسابداري آب در محدوده مطالعاتي مشهد
Water Resources Assessment Using an Integrated Approach Based on Water Accounting, A Case Study of Mashhad Plain Assessment is both a fundamental step in integrated water resources management and one of the most importan...
بررسی فنی و اقتصادی هزينههای استفاده از آب خاکستری در ساختمانهای بلند مرتبه ايران
Economic and Technical Investigation of Grey Water Reuse in High-Rise Buildings in Iran Abstract Iran is located in an arid and semi-arid zone with limited water resources. In urban areas where water supplies are sho...
اثر تغييرات غير خطي افت سرعت در مرحله پمپاژ بر ميزان دبي پمپاژي در پمپهاي رم
Effect of Non-linear Velocity Loss Changes in Pumping Stage of Hydraulic Ram Pumps on Pumping Discharge Rate The ram pump is a device which pumps a portion of input discharge to the pumping system in a significant heigh...