Calculation Methods of Standard Surface Area of Flat Roofs for Internal Wasteway through Cast Iron Pipe and Funnel Set-point Diameters in the Transcarpathian Region

Journal Title: Металлические конструкции - Year 2017, Vol 23, Issue 1

Abstract

The calculation of standard surface areas of flat roofs made by SNiP II-32-74 and DBN V.2.5-75 2013 and according to data III B and IV climatic regions excluding the results of observations of precipitation at 9 weather stations of Transcarpathian region. For the standard surface area calculation of flat roofs it is suggested using materials observations of rainfall in 1889–2014 years in at 9 weather stations of the Trans¬carpathian region with appropriate heights above the Baltic Sea: Coast – 113.0 m, Uzhhorod – 114.6 m, Big Bereznyj – 209.0 m, Hust – 166.0 m, Rachel – 438.0 m, Intermountain – 456.0 m, Lower Gate – 500.0 m, Lower Jelly – 615.0 m, Play – 1 330.0 m. To calculate rainfall parameters for settlements, peaks and bridgewalls of Carpathians it has been suggested using 23 areas between 9 weather stations and 18 transition stations for which precipitation parameters defined at least in two directions between stations and altitude rainfall efficiency. In particular, it has been calculated the rainfall parameters for the 8 peaks of Carpathian Mountain: Valley Llevel – 1 470 m, Big Top – 1 598 m, Tempe – 1 634 m, Unharyaska – 1 707 m, Syvulya, Thick – 1 818 m, Pip Ivan – 1 936 m, Petros – 2 020 m and Goverla – 2 061 m. The calculation of rainwater parameters for cast-iron water pipes and funnels has been made in four areas: Coast – Playa, Uzhgorod – Playa, Hoost – Play, V. Bereznyy – Play. For the purpose of legal practice areas of flat roofs for cast-iron pipes and funnels offered peg 13 districts of Transcarpathian region 9 weather stations.

Authors and Affiliations

Yaroslav Huk

Keywords

Related Articles

Accounting of Constructive Features Nodes Compound Based Stable Central Compressed Rods Structural Coverage

In the article the results of research of influence of constructive decisions of nodal connections of structural designs on the critical forces and form of buckling failure by center-compression element of covering have...

Numerical Researches of the Prop of a 65 kW Wind Power Plant

This article presents the results of numerical research of the steel lattice support of a wind power plant (WPP) from angle profile. The main purpose of the work was to determine the forces and displacements from the act...

The Loads and Actions Effects on the Decision of Narrow-Band Antenna Support Design Shape

The article analyzes the impact of loads and actions effects on the decision of narrow-band antenna support design shape of radio relay communication, it has been analyzed the group of tower supports on the design of the...

Technique of Numerical Analysis of the Intense Deformed State of Steel Vertical Cylindrical Tanks with Taking into Account the Defects of Geometrical Form

The work shows a generic geometric and computer simulation algorithm of the actual surface of the tank wall taking into account both General and local geometry imperfections. Proposed integrated approach to the numerical...

Evaluation of the Effect of the Shaping of a Tower Metal Cooling Tower on the Perception of Wind Loads

Тhe article presents an estimation of the influence of the shaping of a tower metal cooling tower on the perception of wind loads. The influence of wind influence on the simplified mathematical model of the metal cooling...

Download PDF file
  • EP ID EP448719
  • DOI -
  • Views 122
  • Downloads 0

How To Cite

Yaroslav Huk (2017). Calculation Methods of Standard Surface Area of Flat Roofs for Internal Wasteway through Cast Iron Pipe and Funnel Set-point Diameters in the Transcarpathian Region. Металлические конструкции, 23(1), 5-14. https://europub.co.uk./articles/-A-448719