Calculations for Adjusting Endogenous Biomarker Levels During Analytical Recovery Assessments for Ligand-Binding Assay Bioanalytical Method Validation

Journal Title: The AAPS Journal - Year 2015, Vol 17, Issue 4

Abstract

It is often necessary to adjust for detectable endogenous biomarker levels in spiked validation samples (VS) and in selectivity determinations during bioanalytical method validation for ligand-binding assays (LBA) with a matrix like normal human serum (NHS). Described herein are case studies of biomarker analyses using multiplex LBA which highlight the challenges associated with such adjustments when calculating percent analytical recovery (%AR). The LBA test methods were the Meso Scale Discovery V-PLEX® proinflammatory and cytokine panels with NHS as test matrix. The NHS matrix blank exhibited varied endogenous content of the 20 individual cytokines before spiking, ranging from undetectable to readily quantifiable. Addition and subtraction methods for adjusting endogenous cytokine levels in %AR calculations are both used in the bioanalytical field. The two methods were compared in %AR calculations following spiking and analysis of VS for cytokines having detectable endogenous levels in NHS. Calculations for %AR obtained by subtracting quantifiable endogenous biomarker concentrations from the respective total analytical VS values yielded reproducible and credible conclusions. The addition method, in contrast, yielded %AR conclusions that were frequently unreliable and discordant with values obtained with the subtraction adjustment method. It is shown that subtraction of assay signal attributable to matrix is a feasible alternative when endogenous biomarkers levels are below the limit of quantitation, but above the limit of detection. These analyses confirm that the subtraction method is preferable over that using addition to adjust for detectable endogenous biomarker levels when calculating %AR for biomarker LBA.

Authors and Affiliations

John F. Marcelletti, Cindy L. Evans, Manju Saxena, Adriana E. Lopez

Keywords

Related Articles

Development of a Tumour Growth Inhibition Model to Elucidate the Effects of Ritonavir on Intratumoural Metabolism and Anti-tumour Effect of Docetaxel in a Mouse Model for Hereditary Breast Cancer

In a mouse tumour model for hereditary breast cancer, we previously explored the anti-cancer effects of docetaxel, ritonavir and the combination of both and studied the effect of ritonavir on the intratumoural concentrat...

Role of plasma lipoproteins in modifying the toxic effects of water-insoluble drugs: Studies with cyclosporine A

Lipoproteins are a heterogeneous population of macromolecular aggregates of lipids and proteins that are responsible for the transport of lipids through the vascular and extravascular fluids from their site of synthesis...

Paradigm Shift in Toxicity Testing and Modeling

The limitations of traditional toxicity testing characterized by high-cost animal models with low-throughput readouts, inconsistent responses, ethical issues, and extrapolability to humans call for alternative strategies...

A Method to Evaluate Fetal Erythropoiesis from Postnatal Survival of Fetal RBCs

Fetal RBCs are produced during a period of very rapid growth and stimulated erythropoiesis under hypoxic intrauterine conditions. Fetal RBC life span varies with gestational age (GA) and is shorter than that in healthy a...

Download PDF file
  • EP ID EP680977
  • DOI  10.1208/s12248-015-9756-2
  • Views 57
  • Downloads 0

How To Cite

John F. Marcelletti, Cindy L. Evans, Manju Saxena, Adriana E. Lopez (2015). Calculations for Adjusting Endogenous Biomarker Levels During Analytical Recovery Assessments for Ligand-Binding Assay Bioanalytical Method Validation. The AAPS Journal, 17(4), -. https://europub.co.uk./articles/-A-680977