Cascaded Seven Levels H-Bridge Inverter Control of DSTATCOM for Compensation of Reactive Power and Harmonics
Journal Title: International Journal of Science and Research (IJSR) - Year 2013, Vol 2, Issue 1
Abstract
The Static Synchronous Compensators (STATCOMs) have been recognized as the most effective solution for dynamic reactive power compensation, voltage stability enhancement and sub synchronous resonance damping purposes in the electric power systems. The STATCOMs in the distribution utilities (DSTATCOMs) are increasingly investigated for dynamic reactive power compensation and power quality improvement in the distribution utilities .This paper presents an investigation of seven-Level Cascaded H - bridge (CHB) Inverter as Distribution Static Compensator (DSTATCOM) in Power System (PS) for compensation of reactive power and harmonics. The advantages of CHB inverter are low harmonic distortion, reduced number of switches and suppression of switching losses. The DST ATCOM helps to improve the power factor and eliminate the Total Harmonics Distortion (THD) drawn from a Non-Liner Diode Rectifier Load (NLDRL). Finally a level shifted PWM (LSPWM) and phase shifted PWM (PSPWM) techniques are adopted to investigate the performance of CHB Inverter. The results are obtained through Matlab / Simulink software package.
Disruptive Behaviour of the Readers: A Study of Mekelle University Main Campus Libraries (Ethiopia)
Disruptive behavior of the Library materials is a problem for libraries all over the world. Book mutilation and theft is intentional removal of books from the library in an unauthorized manner. Theft and mutilation strik...
Energy Storage Methods for Renewable Energy Sources
Energy is an indispensable element for human survival. Most of the energy sources that we are currently using are non-renewable forms of energy. These sources are limited and are exhausting at a fast rate. For non-renewa...
Evaluation of Adsorptive Capacity of Bioadsorbent in Removal of Congo Red from Aqueous Solution
Adsorption techniques are widely used to remove certain classes of pollutants from waters, especially those which are not easily biodegradable. Currently a combination of biological treatment and adsorption on activated...
Modified R-tree Model
In this paper, the modified model of the R-tree structure was suggested. The main difference between classic R-tree structure and the modified model is rejection of the restriction for amount of descendants for each tree...
A Pragmatic Approach to Carrying out Computer Systems Housekeeping Routines
Many computer users use computer systems to carry out their daily activities without recourse to a good maintenance culture. Users do wait until their systems stopped working before they begin to run from one pole to ano...