CFD Analysis of Solar Air Heater for Enhancenment of Heat Transfer Through Inclined Rib Roughness

Abstract

A 3-dimensional CFD analysis has been carried out of solar air heater to study heat transfer and fluid flow behavior in a rectangular duct of a solar air heater with one roughened wall having combination of circular and square transverse wire rib roughness. The effect of Reynolds number, roughness height, roughness pitch, relative roughness pitch and relative roughness height on the heat transfer coefficient and friction factor have been studied. In order to validate the present numerical model, results have been compared with available experimental results under similar flow conditions. CFD Investigation has been carried out in medium Reynolds number flow.Average Nusselt number increases with an increase of Reynolds number. The maximum value of average Nusselt number is found to be 128.9646 for relative roughness pitch of 20mm and for relative roughness height of 0.06mm at a higher Reynolds number, 14000. Average friction factor decreases with an increase of Reynolds number. The range of parameters for this study has been decided on the basis of practical consideration of the system and operating conditions. The experiment has covered a Reynolds number Re range of 6000-16000, Relative roughness pitch P e of 8, 10 and 12. Relative angle of attack a 90 =0.3333. Results have been compared with the heated plate without roughness and with the earlier reported inclined rib under similar flow condition to determine the enhancement in heat transfer coefficient and friction factor. Ajay Jain | Prof. H. S. Sahu "CFD Analysis of Solar Air Heater for Enhancenment of Heat Transfer Through Inclined Rib Roughness" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-1 , December 2018, URL: http://www.ijtsrd.com/papers/ijtsrd19057.pdf Direct URL: http://www.ijtsrd.com/engineering/mechanical-engineering/19057/cfd-analysis-of-solar-air-heater-for-enhancenment-of-heat-transfer-through-inclined-rib-roughness/ajay-jain

Authors and Affiliations

Keywords

Related Articles

Study on Green Concrete using Eco Sand and Sugarcane Bagases Ash a Review

In India, solid waste management is currently a burning issue that demands attention. Around 4.4 billion tonnes of solid wastes generate yearly, However, in India agricultural sector alone has generated about 600 million...

India's Legal System has Failed to Learn From Institutional Memory

Indian Judiciary is one of the most known and prominent one all over the world . Being the largest democracy Indian Judiciary is always in Light . "The Constitution of India secures justice to all its citizens apart from...

A Comparative Overview on the Horizontal Axis and the Vertical Axis wind Turbines

Wind energy is a renewable and non conventional source of power generation. It is a clean source of energy with a minimum to zero pollution and thus prevents the environment from deteriorating. The wind energy generation...

Impact on NPAs on the performance of UCO Bank: A Study

Indian banking sector has been facing terrible problem due to the deterioration quality of assets which is increasing gradually. The growth of NPA has a direct impact on the overall performance of the bank. The problems...

Data Imputation by Soft Computing

Data imputing uses to posit missing data values, as missing data have a negative effect on the computation validity of models. This study develops a genetic algorithm (GA) to optimize imputing for missing cost data of fa...

Download PDF file
  • EP ID EP446427
  • DOI -
  • Views 65
  • Downloads 0

How To Cite

(2018). CFD Analysis of Solar Air Heater for Enhancenment of Heat Transfer Through Inclined Rib Roughness. International Journal of Trend in Scientific Research and Development, 3(1), 662-667. https://europub.co.uk./articles/-A-446427