Cfd Analysis on Concentric Tube Heat Exchanger in Parallel and Counter Flow Direction

Abstract

A Heat Exchanger is a device which is used to transfer heat from one fluid to another, whether the fluids are separated by a solid wall so that they never mix, or the fluids are directly in contact. Every year Heat exchanger technology is growing to develop efficient, compact and economical heat exchangers, all over the world. Updating the community for this development needs an interaction. These days concentric tube heat exchangers are used with forced convection for lowering the working fluid’s temperature by raising the cooling medium’s temperature.The purpose of this project is to use ANSYS FLUENT 17.1 software and theoretical calculations to analyse the temperature drops as a function of both inlet velocity and inlet temperature and how each varies with the other. Each heat exchanger model was designed and simulated for both parallel flow and counter flow heat exchanger models. The results were compared between parallel and counter flow heat exchangers. CFD analysis was utilized to find the outlet temperatures of parallel and counter flow heat exchangers for the inlet velocity and inlet temperature of the fluid medium used. "Computational Fluid Dynamics (CFD) is a science of predicting fluid flow, heat transfer, mass transfer, and related phenomena by solving the mathematical equations which govern these processes using a numerical processes". These outlet temperature values obtained were used to determine the overall heat transfer coefficient. Theoretical calculations are done by the values obtained through the experiment conducted on the heat exchanger setup for both parallel and counter flow.

Authors and Affiliations

Sneha. H. Dhoria, E. Manoj Kumar, I. V. S. Yeswanth, Lakshmi Jayanti

Keywords

Related Articles

Assessment of Particles of Varied Soil By Grain Size Analysis – A Case Study in Jabalpur M.P.

Grain size distribution plays a vital role for characterization of soil. Particle size distribution (PSD) in a soil mass is a character which gives a major idea about bearing capacity of soils and bearing capacity of the...

Dielectric Properties of Compatibilised EPDM/Silicone rubber Nanocomposites

EPDM/Silicone rubber nanocomposites are prepared by incorporating various phr of organically modified montmorillonite (OMMT) nanoclay onto compatibilised and uncompatibilised EPDM/Silicone rubber blends using two roll mi...

Underwater Welding Techniques

Welding demand in offshore and marine applications is increased with the increasing in oil and gas activities as well as increasing in the marine transportation and industrial applications. Applications of underwater wel...

A Review of Strategies to Promote Road Safety in Rich Developing Countries: The GCC Countries Experience

Road safety policies, strategies and action plans, along with trends in road traffic injuries (RTIs) in the oil-rich Gulf Cooperative Council (GCC) countries were examined to appraise their road safety work with an overa...

Comparative Analysis of Pso-Pid and Hu-Pid

PID control is an important ingredient of a distributed control system. The controllers are also embedded in many special purpose control systems. PID control is often combined with logic, sequential functions, selectors...

Download PDF file
  • EP ID EP394352
  • DOI 10.9790/9622-0806022025.
  • Views 91
  • Downloads 0

How To Cite

Sneha. H. Dhoria, E. Manoj Kumar, I. V. S. Yeswanth, Lakshmi Jayanti (2018). Cfd Analysis on Concentric Tube Heat Exchanger in Parallel and Counter Flow Direction. International Journal of engineering Research and Applications, 8(6), 20-25. https://europub.co.uk./articles/-A-394352