Changes of end-tidal carbon dioxide during cardiopulmonary resuscitation from ventricular fibrillation versus asphyxial cardiac arrest

Journal Title: World Journal of Emergency Medicine - Year 2014, Vol 5, Issue 2

Abstract

BACKGROUND: Partial pressure of end-tidal carbon dioxide (PETCO2) has been used to monitor the effectiveness of precordial compression (PC) and regarded as a prognostic value of outcomes in cardiopulmonary resuscitation (CPR). This study was to investigate changes of PETCO2 during CPR in rats with ventricular fibrillation (VF) versus asphyxial cardiac arrest. METHODS: Sixty-two male Sprague-Dawley (SD) rats were randomly divided into an asphyxial group (n=32) and a VF group (n=30). PETCO2 was measured during CPR from a 6-minute period of VF or asphyxial cardiac arrest. RESULTS: The initial values of PETCO2 immediately after PC in the VF group were significantly lower than those in the asphyxial group (12.8±4.87 mmHg vs. 49.2±8.13 mmHg, P=0.000). In the VF group, the values of PETCO2 after 6 minutes of PC were significantly higher in rats with return of spontaneous circulation (ROSC), compared with those in rats without ROSC (16.5±3.07 mmHg vs. 13.2±2.62 mmHg, P=0.004). In the asphyxial group, the values of PETCO2 after 2 minutes of PC in rats with ROSC were significantly higher than those in rats without ROSC (20.8±3.24 mmHg vs. 13.9±1.50 mmHg, P=0.000). Receiver operator characteristic (ROC) curves of PETCO2 showed significant sensitivity and specificity for predicting ROSC in VF versus asphyxial cardiac arrest. CONCLUSIONS: The initial values of PETCO2 immediately after CPR may be helpful in differentiating the causes of cardiac arrest. Changes of PETCO2 during CPR can predict outcomes of CPR.

Authors and Affiliations

Keywords

Related Articles

Changes of the immunological barrier of intestinal mucosa in rats with sepsis

BACKGROUND: Sepsis has become the greatest threat to in-patients, with a mortality of over 25%.The dysfunction of gut barrier, especially the immunological barrier, plays an important role in the development of sepsis. T...

Drug calculation ability of qualified paramedics: A pilot study

BACKGROUND: The inability of paramedics to perform accurate calculations may result in a compromise of patient safety which may result from under or over dosing of drugs, incorrect joules for defibrillation, or a major a...

Association of low non-invasive near-infrared spectroscopic measurements during initial trauma resuscitation with future development of multiple organ dysfunction

BACKGROUND: Near-infrared spectroscopy (NIRS) non-invasively monitors muscle tissue oxygen saturation (StO2). It may provide a continuous noninvasive measurement to identify occult hypoperfusion, guide resuscitation, and...

Ascending aortic dilatation rate after transcatheter aortic valve replacement in patients with bicuspid and tricuspid aortic stenosis: A multidetector computed tomography follow-up study

BACKGROUND: Current data is lacking about the progression of ascending aortic dilatation after transcatheter aortic valve replacement (TAVR) in aortic stenosis (AS) patients with bicuspid aortic valve (BAV) and tricuspid...

Prehospital response to respiratory distress by the public ambulance system in a Ukrainian city

BACKGROUND: The capability of the public ambulance system in Ukraine to address urgent medical complaints in a prehospital environment is unknown. Evaluation using reliable sources of patient data is needed to provide in...

Download PDF file
  • EP ID EP470575
  • DOI -
  • Views 56
  • Downloads 0

How To Cite

(2014). Changes of end-tidal carbon dioxide during cardiopulmonary resuscitation from ventricular fibrillation versus asphyxial cardiac arrest. World Journal of Emergency Medicine, 5(2), 116-121. https://europub.co.uk./articles/-A-470575