Characterization of Knee Joint Diseases Using Medical Ultrasound and Magnetic Resonance Imaging
Journal Title: International Journal of Science and Research (IJSR) - Year 2015, Vol 4, Issue 4
Abstract
"Abstract Background: Ultrasound (US) has been advocated for the assessment of soft tissue supporting structures of the knee joint, because it's a simple, rapid, cheap, accurate method and well accepted by patient in comparison to Magnetic Resonance Imaging (MRI). This study was aimed to determine the characterization of incidence of knee joint diseases, with US compared to MRI, in Radiological Center, College of Applied Medical Sciences, King Khalid University (KKU), Saudi Arabia, in patients with knee joint symptoms. Method: A cross sectional descriptive study on the sonographic pattern of knee joint diseases was performed to assess characterization of knee joint diseases at Radiological Center, College of Applied Medical Sciences, King Khalid University(KKU), Saudi Arabia, of 124 patients from October 2011 to August 2014. US technique has been carried out according to the protocol of American Institute of Ultrasound in Medicine (AIUM), using a linear probe transducer with high frequency 7.5 to 12MHz. Result: A total of 124 patients with knee joint disorders were evaluated with US and MRI. The age range was from 12 to 80 years. The mean age was 38 years and median 36 years. The commonest presenting symptom was painful swelling of the knee joint. US revealed characterization frequency per individual, was: hyper echoic 4 (3.2%), hypo echoic 6 (4.8%) an echoic 102 (82.3%), echogenic 2 (1.6%) and none seen of other diseases 10 (8.1%) and MRI characterization frequency individuals, was: high signal 102 (82.3%) and low signal 22 (17.7%)."
Accident Analysis on NH-18 by Using Regression Model and its Preventive Measures
"Road accidents are one of the main causes of deaths worldwide. About half a million people are killed in road related crashes every year throughout the world. The probability of an accident occurring is influenced by nu...
PWM STATCOM Based Reactive Power Control by Using a Modular Multilevel Cascade Converter
The closed loop reactive power control by a Sinusoidal Pulse Width Modulation (SPWM) technique based static synchronous compensator (STATCOM) is used in modular multilevel cascade converter for reactive power control for...
Highly Secure Method for Image Transmission Using Partition and Multi Encryption Technique
In present times, the protection of multimedia data is becoming very important. The protection of this multimedia data can be done with encryption. There are so many different techniques should be used to protect confide...
Single Component Adsorption of Nickel, Cadmium, Copper and Lead from Aqueous Solution Using Aswan Clay
"Metals discharged to wastewater pose a great threat to environment. Treatment for such metals contaminated wastewater is a must. Aswan clay (AC) was tested as adsorbent for the adsorption of Ni(II), Pb(II), Cd(II) and...
A Repetitive Sparce Matrix Converter with Z-Source Network to having less Current THD
This paper proposed a new sparce matrix converter with Z-source network to provide unity voltage transfer ratio. It is an ac-to-ac converter with diode-IGBT bidirectional switches. The limitations of existing matrix conv...