Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth

Journal Title: Journal of Clinical and Diagnostic Research - Year 2017, Vol 11, Issue 9

Abstract

Introduction: Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These NiTi instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. Aim: To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Materials and Methods: Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. Results: No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. Conclusion: The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary teeth.

Authors and Affiliations

Lavanya Govindaraju, Ganesh Jeevanandan, EMG Subramanian

Keywords

Related Articles

Hybrid Doctors: The Need Risen From Informed Patients

In the last decade, we have seen a significant surge in the number of patients whom we can term as “Informed patients”. Informed patients are well read on the medical condition that they are looking to resolve. They may...

Evaluation of ECG Abnormalities in Patients with Asymptomatic Type 2 Diabetes Mellitus

Introduction: Diabetes Mellitus (DM) is the most common chronic disease. DM is considered a Cardiovascular Disease (CVD) risk equivalent. Its macrovascular complications are associated with two-fold increased risk of pre...

Prediction of Peak Aerobic Power among Costa Rican Older Adults

ABSTRACT Introduction: The peak oxygen uptake (VO2peak) is considered a valid indicator of the cardiovascular system function, and when measured on a metabolic cart it is considered the gold standard for cardiorespirator...

A Novel Technique of Fabricating a Modified Removable Provisional Prosthesis over an Autologous Bone Grafted Maxillary Anterior Edentulous Segment Prior to Implant Placement

Implant dentistry has provided a lot of surgical as well as prosthetic techniques for improving the success of the implants. The surgical technique commonly followed now prior to implant placement is bone grafting proced...

Prevalence of Intestinal Parasitic Infections among Pulmonary Tuberculosis Patients in a Tertiary Care Hospital, Bhubaneswar, Odisha, India

ABSTRACT Introduction: In developing countries like India, Intestinal Parasitic Infections (IPIs) and Tuberculosis (TB) co-infection have been perceived to be high. The geographic distributions of helminths and TB overla...

Download PDF file
  • EP ID EP363726
  • DOI 10.7860/JCDR/2017/30069.10602
  • Views 61
  • Downloads 0

How To Cite

Lavanya Govindaraju, Ganesh Jeevanandan, EMG Subramanian (2017). Clinical Evaluation of Quality of Obturation and Instrumentation Time using Two Modified Rotary File Systems with Manual Instrumentation in Primary Teeth. Journal of Clinical and Diagnostic Research, 11(9), 55-58. https://europub.co.uk./articles/-A-363726