Closed Loop Control of the Three Switch Serial Input Interleaved Forward Converter Fed Dc Drive

Abstract

This paper deals with the closed loop control of the three switch Interleaved Forward Converter with motor load. When any step change occurs at the input of the open loop three switch interleaved forward converter, the output is also disturbed. In order to avoid this, a closed looped control is introduced. By using the closed loop control, the steady state error in speed is reduced. The DC input is converted into high frequency AC using the Forward Converter. The high frequency AC is rectified using a Half-wave rectifier and the output voltage is regulated using the closed loop system. The results of closed loop system are compared with the open loop system.

Authors and Affiliations

R. Lakshmi, Dr Joseph Henry, Dr K. Rajan

Keywords

Related Articles

Fault Detection in an Induction Motor Drive Using Discrete Wavelet Packet Transform

The aim of this study is to employ the wavelet technique for diagnosis of open-circuit and short circuit faults in the dc link of Induction motor drive. The symlet wavelet is selected as the wavelet base to perform stato...

Output Voltage Control of PI And Fuzzy Logic Based Zeta Converter

The Zeta converters are being used in different industrial applications day by day. Most of the researches on DC converters focus on such issues as the determination of the control system that most effectively controls a...

Hierarchical Steady State Control of System wide Distributed Multi-FACTS Devices for Operational Enhancement Objectives

Developed power systems in the world are well meshed with local, inter-regional and international connection making the increasing complex to operate. With advancement in power electronics, the control of these systems a...

On Commercially Relevant Research In Indian EE R&D Ecosystem

Commercially relevant research in Electrical and Electronics (EE) Research and Development (R&D) ecosystem has become essential to boost India’s EE manufacturing. In India, EE product sell is regulated under Electronics...

Tuning of PI and PID Controller with STATCOM, SSSC and UPFC for Minimizing Damping of Oscillation

This paper presents the comparative performance of directly and feedback connected PI and PID controller scheme with Flexible AC Transmission System (FACTS) devices, such as Static Synchronous Compensator (STATCOM), Stat...

Download PDF file
  • EP ID EP388506
  • DOI 10.9790/1676-1206037175.
  • Views 125
  • Downloads 0

How To Cite

R. Lakshmi, Dr Joseph Henry, Dr K. Rajan (2017). Closed Loop Control of the Three Switch Serial Input Interleaved Forward Converter Fed Dc Drive. IOSR Journals (IOSR Journal of Electrical and Electronics Engineering), 12(6), 71-75. https://europub.co.uk./articles/-A-388506