Commissioning of two different algorithms for stereotactic Radiosurgery M6 FI+ CyberKnife system

Journal Title: International Journal of Medical Research and Review - Year 2018, Vol 6, Issue 8

Abstract

Introduction: Cyber Knife M6 FI+ a very precise robotic stereotactic radiosurgery system which is capable of delivering very high radiation dose to the tumour while minimizing radiation exposure to normal organs and tissues. MultiPlan treatment planning system is used with the CyberKnife unit and the algorithms used for optimization are Ray-Tracing and Monte Carlo. Our CyberKnife M6 FI+ system commissioning is done as per the vendor recommendation and meeting the local regulatory guidelines. Materials and Methods: Clinical beam data measurement is carried out using Radiation Field Analyzer, Diode E, Pinpoint chamber, Semiflex ionization chamber and Unidose E Electrometer. FC-65 ionization chamber used in absolute dose calibration. The mechanical accuracy of the robot and image stability was verified using Radiochromic film (EBT3), E2E and Iris QA toolkits along with software. StereoPHAN is used for the patient-specific QA point dose measurement. Results: Tissue phantom ratio, Off-centre ratio, Output factor, Percentage depth dose, open beam profile and absolute dose calibration are done as per the protocols. E2E performed for two different modes- static and motion. Iris aperture size measured for all the field sizes. The patient-specific QA delivered for both algorithms. Discussion: Clinical beam data measurements are within ±1% of composite data set, overall standard deviation for Output Factors of the fixed and Iris collimators are 0.0026 and 0.0063. The absolute dose was calibrated to 1cGy per MU. E2E, Iris QA and Laser and radiation coincidence values are within the tolerance. Patient-specific QA point dose measurement variation for Ray-Tracing and Monte Carlo is 3% and 2%. Conclusion: These exercises are mandatory to achieve the accurate, precise and high quality of treatment which also includes patient safety.

Authors and Affiliations

Mageshraja Kannan, Jefy Ninan, Prasobh Chandrasenan, Subodh Chandra Pande, Aditya Gupta, Harpreet Kaur, Ajay Khatri

Keywords

Related Articles

Alpha 2 agonist dexmedetomidine as an adjuvant to bupivacaine in supraclavicular brachial plexus block

Background: Regional anesthesia is a recommended technique for upper limb surgeries with better postoperative profile. Alpha-2 agonists are added to local anesthetic agents to extend the duration of nerve blocks. We eval...

The relationship between blood sugar levels (glycosylated haemoglobin) and the risk of development of diabetic retinopathy

Introduction: Diabetic retinopathy is a major cause of visual impairment and blindness in India and with its early detection and timely treatment, the risk of visual loss can be reduced significantly. Onset and progressi...

Pattern of inflammatory phenotypes using sputum cytology among patients with asthma in a tertiary care centre, Kerala –A prospective cohort study

Background: Asthma is a chronic inflammatory airway disease in which various inflammatory cells play a pivotal role in pathogenesis. Based on the inflammatory cells count in the sputum, various inflammatory phenotypes a...

Biomedical waste management- an overview

Biomedical waste management system is poor in most of the hospital. There is urgent need to increase awareness related with this issue in all the hospital staff

Significance of lactate dehydrogenase in prediction of pregnancy induced hypertension and its complications

Objectives: To compare serum Lactate Dehydrogenase (LDH) level of normotensive pregnant women with those of preeclamptic and eclamptic women. To determine the relationship of levels of serum Lactate dehydrogenase with se...

Download PDF file
  • EP ID EP486773
  • DOI 10.17511/ijmrr.2018.i08.13.
  • Views 181
  • Downloads 0

How To Cite

Mageshraja Kannan, Jefy Ninan, Prasobh Chandrasenan, Subodh Chandra Pande, Aditya Gupta, Harpreet Kaur, Ajay Khatri (2018). Commissioning of two different algorithms for stereotactic Radiosurgery M6 FI+ CyberKnife system. International Journal of Medical Research and Review, 6(8), 477-486. https://europub.co.uk./articles/-A-486773