Comparative Evaluation of the Dimensional Accuracy of Closed Tray and Open Tray Impression Technique for Dental Implants using Two Different Impression Materials

Journal Title: Journal of Clinical and Diagnostic Research - Year 2018, Vol 12, Issue 11

Abstract

ABSTRACT Introduction: In the era of fixed prosthodontics where implant restorations are being routinely used, it is imperative for the dentist to correctly record the position and orientation of the implant. This necessitates the application of correct impression procedure, impression material and accurate die materials. Aim: This study aims at evaluating and comparing the effect of closed tray and open tray impression technique with polyvinyl siloxane and polyether as impression materials on the dimensional accuracy of implant definitive casts. Materials and Methods: This in vitro study is about implant definitive casts made using the open tray and closed tray impression technique using two different impression materials i.e., polyvinyl siloxane and polyether. The Co-ordinate measuring machine was used to evaluate the dimensional accuracy of the casts, then tested at the Tata Autocomponents-Interiors and Plastic Division (IPD), Pune. A total of 60 implant definitive casts were made. A total of 30 casts were made using each impression technique. These casts were further subgrouped wherein, 15 casts were made using polyvinyl siloxane as the impression material and 15 casts were made using polyether. The unpaired t-test was used for comparison. Results: Both the open tray and closed tray impression technique are comparable to each other and there is no statistically significant difference between the two. Also, the impression materials are equally good for impression making of implants (p>0.05). Conclusion: Either of the impression techniques and material used in the study can be used to make implant definitive casts.

Authors and Affiliations

Arpita Tandon, Nilesh S Bulbule, Amit K Jagtap, Dilip M Kakade

Keywords

Related Articles

Adult Survival in Ellis-van Creveld Syndrome with Common Atrium – A Rare Case Report

Ellis-van Creveld syndrome is a rare genetic disorder, characterized by chondral dysplasia, ectodermal dysplasia, polydactyly and congenital heart defects. Patients with this syndrome rarely survive into adulthood. The s...

Gastroesophageal Reflux Disease and its Association with Body Mass Index: Clinical and Endoscopic Study

Introduction: Obesity is rapidly becoming a pandemic and poses a serious health risk to the individuals. Abdominal obesity is quite common in India and is a prime risk factor for diseases like diabetes, coronary artery d...

Subcutaneous Basidiobolomycosis in an Immunocompetent Child

ABSTRACT Basidiobolus ranarum is a fungus belonging to Basidiobolus genera, Entomophthorales order and Zygomycetes class. It is present in soil, decaying vegetable matter, intestines of amphibians, reptiles, fish and ins...

Assessing the Impact of a Structured Tuberculosis Training Activity on the Knowledge and Attitude of Community Volunteers

ABSTRACT Introduction: With the paucity of health workforce for Tuberculosis (TB) in India a cadre of trained community volunteers can effectively contribute to the prevention and control of TB in a particular community....

An Innovative Technique to Evaluate Quantitative Pupillary Light Reflex by Dynamic Pupillometry using Infrared Videography

ABSTRACT Introduction: An innovative approach was designed to quantify the pupillary light reflex using infrared and white light illumination. This method is convenient to detect pupil edges, area and the diameter of pup...

Download PDF file
  • EP ID EP526386
  • DOI 10.7860/JCDR/2018/36235.12296
  • Views 64
  • Downloads 0

How To Cite

Arpita Tandon, Nilesh S Bulbule, Amit K Jagtap, Dilip M Kakade (2018). Comparative Evaluation of the Dimensional Accuracy of Closed Tray and Open Tray Impression Technique for Dental Implants using Two Different Impression Materials. Journal of Clinical and Diagnostic Research, 12(11), 34-38. https://europub.co.uk./articles/-A-526386