Comparative Study of Haemodynamic Response to Intubation with McCoy laryngoscope, Intubating LMA and Vividtrac® Videolaryngoscope in Controlled Hypertensive Patients
Journal Title: Indian Journal of Anesthesia and Analgesia - Year 2019, Vol 6, Issue 4
Abstract
Laryngoscopy and intubation can result in significant haemodynamic response which is even more exaggerated in hypertensive patients. The magnitude of cardiovascular response is directly related to the force applied and duration of laryngoscopy. Various airway devices and drugs have been tried to limit this pressor response. We conducted a prospective, randomized study to compare haemodynamic response to intubation using McCoy laryngoscope, Intubating Laryngeal Mask Airway (ILMA) and VividTrac® videolaryngoscope in patients with controlled hypertension requiring general anaesthesia for various surgeries. Methods: The study included 90 controlled hypertensive patients of either sex, belonging to ASA grade II, between age group of 40-60 years, requiring general anaesthesia were divided into three groups. In group M, patients were intubated with McCoy laryngoscope. In group L, patients were intubated with intubating LMA. In group V, patients were intubated using VividTrac® videolaryngoscope. Haemodynamic response following intubation were compared among all the three groups. Intubation time, the success rate of intubation and complications, if any, were also compared in all the three groups. Results: It was observed that VividTrac® videolaryngoscope produced significantly less haemodynamic response compared to intubation with ILMA and McCoy laryngoscope. Intubation using McCoy laryngoscope was found to be comparatively a faster method to secure tracheal intubation when compared to ILMA and videolaryngoscope. Complications, like oesophageal intubation and sore throat were more with intubating LMA, whereas injury to oropharyngeal mucosa was found to be observed with VividTrac® videolaryngoscope. Conclusion: VividTrac® videolaryngoscopy and intubation causes less haemodynamic changes compared to Intubating LMA and McCoy laryngoscopy.
Authors and Affiliations
Sangeetha C
Ebola Virus Disease in the year 2014-2015: Retrospective Study of Suspected Cases of Ebola Virus Disease at Intensive Care Unit of Tertiary Care Center
Aim: Containment of a dangerous and fatal disease outbreak and measures to control in present and future. Design: Retrospective observational Study. Material and Methods: A team of researchers studied the demographic cha...
A Comparative Study of Intrathecal Isobaric 0.5% Ropivacaine with Isobaric 0.5% Bupivacaine in Elective Lower Abdominal and Lower Limb Surgeries
Ropivacaine has a lower and different toxicity profile compared to Bupivacaine. It is a new longacting, enantiomerically pure (Senantiomers), amide local anaesthetic with a high pKa and low lipid solubility. T. Ropivac...
A Comparative Study between 0.5% Bupivacaine with Clonidine Additive and 0.5% Bupivacaine Plain for Brachial Plexus Block by Supraclavicular Aprroach in Upper Limb Surgeries Using Ultrasound Guided Technique
Supraclavicular Brachial plexus block provides safe,effective,low cost anaesthesia with excellent post operative analgesia . The current study was an attempt to compare Bupivacaine 0.5% with Bupivacaine 0.5% plus Clioni...
A Comparative Study to Evaluate the Intubating Conditions between Propofol-Sevoflurane and Propofol Alone Without Using Neuromuscular Blocking Agents
Endotracheal intubation using an induction agent is usually facilitated by the use of depolarizing neuromuscular blocking agents like succinylcholine however it may be associated with various side effects. Propofol and s...
A Comparative Study of Hyperbaric 0.5% Levobupivacaine with Bupivacaine 0.5% for Spinal Anaesthesia in Elective Surgeries
Background: Subarachnoid block is popular and commonly used worldwide. The advantage of an awake patient, minimal drug cost and rapid patient turnover has made this the method of choice for many surgical procedures. Amon...