Comparison of Axial Flux PMSM and Outrunner PMSM under Same Physical and Electrical Parameters according to Cogging Torque

Abstract

Axial flux permanent magnet motor (AFPMM) and outrunner permanent magnet motor (ORPMM) are generic rotating machines that are commonly used. Cogging torque is an undesired output for electrical motors. Although the cogging torque is not an important problem at high operational speed thanks to moment of inertia, it is a serious trouble that must be overcome at low operational speed. Especially, it must be minimized for movement of solar panels on a satellite. Due to the fact that the cogging torque is so important factor for design of permanent magnet synchronous motor, in this study it is only focused on the cogging torque. For that reason, two designed motors are compared according to cogging torque. Thus, it has been shown what type of motor should be preferred for minimum cogging torque desired applications.

Authors and Affiliations

Ali SAYGIN, Ahmet AKSÖZ

Keywords

Related Articles

The Effect of Copper Plating Processes on Corrosion Resistance of Castings Produced from Zinc-Aluminum Alloy

Different surface treatment processes are applied on cast piece made of zinc-aluminum alloys in order to increase their service life and improve their effective use. Among the alternatives, electrochemical coating proces...

AN INVESTİGATION ON THE USAGE OF THE PATENT SEARCH ENGİNES

Patent documents are very valuable scientific resources. They store recent and detailed technical knowledge in all technological fields. While the importance of the patent rights is understood better day by day, the numb...

Array Feed Parabolic Reflector Antennas Design Having Low Near Sidelobe and Backlobe Levels

Antennas which are one of the most important components that designate the system characteristic in radar systems, nowadays have a substantial position in military as well as civil areas. Due to their narrow beamwidth an...

The Comparision of Heating and Cooling Performance of a Serial and Parallel Connected Counter Flow Ranque–Hilsch Vortex Tube

In this study, two counter flow Ranque-Hilsch Vortex Tubes with body length 100 mm and inlet diameter 7 mm were used having no moving parts except a control valve for adjustment of volume flow rates. Six-orifice nozzles...

Traditional City Pattern and Houses of Çanakkale-Bozcaada

Looking closely to Bozcaada architectural characteristics, it is possible to see Turkish and Rum influence. For instance, the houses in Alaybey neighborhood have the architectural characteristics of the former, while the...

Download PDF file
  • EP ID EP491147
  • DOI 10.29109/http-gujsc-gazi-edu-tr.400070
  • Views 108
  • Downloads 0

How To Cite

Ali SAYGIN, Ahmet AKSÖZ (2018). Comparison of Axial Flux PMSM and Outrunner PMSM under Same Physical and Electrical Parameters according to Cogging Torque. Gazi Üniversitesi Fen Bilimleri Dergisi Part C: Tasarım ve Teknoloji, 6(3), 659-667. https://europub.co.uk./articles/-A-491147