Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension

Journal Title: International Journal of Ophthalmology - Year 2017, Vol 10, Issue 4

Abstract

"AIM: To compare the diagnostic performance of isolated-check visual evoked potential (icVEP) and standard automated perimetry (SAP), for evaluating the application values of icVEP in the detection of early glaucoma. METHODS: Totally 144 subjects (288 eyes) were enrolled in this study. icVEP testing was performed with the Neucodia visual electrophysiological diagnostic system. A 15% positive-contrast (bright) condition pattern was used in this device to differentiate between glaucoma patients and healthy control subjects. Signal-to-noise ratios (SNR) were derived based on a multivariate statistic. The eyes were judged as abnormal if the test yielded an SNR≤1. SAP testing was performed with the Humphrey Field Analyzer II. The visual fields were deemed as abnormality if the glaucoma hemifield test results outside normal limits; or the pattern standard deviation with P<0.05; or the cluster of three or more non-edge points on the pattern deviation plot in a single hemifield with P<0.05, one of which must have a P<0.01. Disc photographs were graded as either glaucomatous optic neuropathy or normal by two experts who were masked to all other patient information. Moorfields regression analysis (MRA) used as a separate diagnostic classification was performed by Heidelberg retina tomograph (HRT). RESULTS: When the disc photograph grader was used as diagnostic standard, the sensitivity for SAP and icVEP was 32.3% and 38.5% respectively and specificity was 82.3% and 77.8% respectively. When the MRA Classifier was used as the diagnostic standard, the sensitivity for SAP and icVEP was 48.6% and 51.4% respectively and specificity was 84.1% and 78.0% respectively. When the combined structural assessment was used as the diagnostic standard, the sensitivity for SAP and icVEP was 59.2% and 53.1% respectively and specificity was 84.2% and 84.6% respectivlely. There was no statistical significance between the sensitivity or specificity of SAP and icVEP, regardless of which diagnostic standard was based on. CONCLUSION: The diagnostic performance of icVEP is not better than that of SAP in the detection of early glaucoma."

Authors and Affiliations

Ying-Xi Zhao

Keywords

Related Articles

Efficacy of autologous conjunctival flap on repairing the late-onset filtering bleb leakage

"AIM: To evaluate the effectiveness of autologous conjunctival flap surgery for repairing the late-onset filtering bleb leakage after trabeculectomy. METHODS: This study retrospectively reviewed 106 eyes from 106 patient...

Efficacy of selective laser trabeculoplasty following incisional glaucoma surgery

"AIM: To evaluate the efficacy of selective laser trabeculoplasty (SLT) in glaucomatous eyes with previous incisional glaucoma surgery. METHODS: A retrospective cohort of eyes that underwent SLT at a single institution f...

Protective effects of ciliary neurotrophic factor on the retinal ganglion cells by injure of hydrogen peroxide

"AIM: To explore the effect of ciliary neurotrophic factor (CNTF) on retinal ganglion cell (RGC)-5 induced by hydrogen peroxide (H2O2). METHODS: After cell adherence, RGC-5 culture medium was changed to contain different...

A Chinese family with Axenfeld-Rieger syndrome: report of the clinical and genetic findings

"AIM: To describe a Chinese family affected by a severe form of Axenfeld-Rieger syndrome (ARS) and characterize the molecular defect in PITX2 in the family. METHODS: Patients presented with typical ARS from a Chinese fam...

Effects of lens extirpation with anterior vitrectomy on vitreous three-dimensional mesh structure

"AIM: To investigate the changes in vitreous gel structure after lens extirpation combined with anterior vitrectomy in rabbit eyes. METHODS: Twenty-eight chinchilla rabbits were divided into three groups. The control gro...

Download PDF file
  • EP ID EP605171
  • DOI 10.18240/ijo.2017.04.16
  • Views 53
  • Downloads 0

How To Cite

Ying-Xi Zhao (2017). Comparison of isolated-check visual evoked potential and standard automated perimetry in early glaucoma and high-risk ocular hypertension. International Journal of Ophthalmology, 10(4), -. https://europub.co.uk./articles/-A-605171