Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia

Journal Title: International Journal of Ophthalmology - Year 2019, Vol 12, Issue 5

Abstract

This study was designed to compare optical biometry measurements and predicted refraction in cataract patients with high myopia [axial length (AL) ≥26 mm] using OA-2000 and IOL Master 500. Ocular biometry measurements were performed using both biometers before surgery. Uneventful cataract surgery was performed in all patients. Postoperative manifest refraction was obtained 3wk after surgery or later. A total of 67 eyes were examined. The AL, keratometry (K), and anterior chamber depth (ACD) of the two biometers showed excellent agreement. Predicted errors were similar and a strong positive correlation was observed (r=0.909). Out of 21 eyes (31.34%) with unsuccessful AL readings using the IOL Master 500, 20 eyes of them could be measured using OA-2000. Therefore, the biometric parameters measured by the two biometers showed good agreement. However, OA-2000 had a lower AL measurement failure rate.

Authors and Affiliations

Ming-Zhi Zhang

Keywords

Related Articles

Melatonin concentrations in serum of primary glaucoma patients

"AIM: To determine whether glaucoma patients exhibit an abnormal melatonin concentration in serum and the effects of psychiatric disorders caused by glaucoma in melatonin secretion. METHODS: A sample of 80 primary angle-...

Corneal topographic changes and surgically induced astigmatism following combined phacoemulsification and 25-gauge vitrectomy

"AIM: To evaluate corneal topographic changes and surgically induced astigmatism (SIA) after combined phacoemulsification and 25-gauge transconjunctival sutureless vitrectomy (25-G TSV). METHODS: A retrospective study on...

Dose-dependent effects of NMDA on retinal and optic nerve morphology in rats

"AIM: To investigate dose-dependent effects of N-methyl-D-aspartate (NMDA) on retinal and optic nerve morphology in rats. METHODS: Sprague Dawley rats, 180-250 g in weight were divided into four groups. Groups 1, 2, 3 an...

Paired eye-control study of unilateral opaque bubble layer in femtosecond laser assisted laser in situ keratomileusis

"AIM: To investigate the predictive factors of the opaque bubble layer (OBL) compared to the fellow eye of same patients in FS200 femtosecond laser assisted laser in situ keratomileusis (FS-LASIK). METHODS: This study co...

Download PDF file
  • EP ID EP618063
  • DOI 10.18240/ijo.2019.05.23
  • Views 63
  • Downloads 0

How To Cite

Ming-Zhi Zhang (2019). Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia. International Journal of Ophthalmology, 12(5), 844-847. https://europub.co.uk./articles/-A-618063